1.5.2 CAN j1939/S6 digital interface specifications and protocols
Specifications of CAN j1939/S6
digital interface correspond to
. Data transfer protocols is based on SAE J1939 standard and meets its
requirements.
Configuration of MasterCAN DAC connection options via S6 Technology, as well as selection
of necessary
is performed via K-Line interface (ISO 14230) using
Servicse S6 MasterCAN software (can be downloaded from
MasterCAN DAC receives/transmits data automatically (default mode) or on request.
Baudrate can be selected from the following values: 100; 125; 250; 500; 1000 kbit/s
(default rate
—
250 kbit /s).
After the connection using S6 Technology, unique network addresses (SA) should be
specified for MasterCAN DAC15: 126 or 146 (126 by default), while for
MasterCAN DAC2113: 127 or 147 (127 by default).
Detailed information regarding the architecture of CAN j1939/S6 Telematics interface is
provided in its