Summary of Contents for TEC601

Page 1: ...DOC NO PRMAN 0025 TEC601 Rev 04 01 210203 docx E OE TEC601 3 Zone 19 inch Rack Extinguishing Control Panel Rev 04 01 ...

Page 2: ...___________________________________________________ 9 12 SERVICE AND MAINTENANCE ________________________________________________________ 10 12 1 Maintenance Schedule ___________________________________________________________ 10 12 1 1 Daily Actions ___________________________________________________________________ 10 12 1 2 Monthly Actions _______________________________________________________...

Page 3: ...01 also provides relay outputs for the monitoring of Fire Fault and Discharge conditions A third fire detection zone is also available which can be used to connect to an additional detector that may be positioned elsewhere in the equipment cabinet A power output for the equipment rack Air Handling Unit AHU is also provided to allow the TEC601 to shut down the air handling unit just before the rele...

Page 4: ...g Control Panel INSTALLATION OPERATION MANUAL PRMAN 0025 TEC601 Rev 04 01 210203 docx E OE 2 4 GENERAL ASSEMBLY FIGURE 1 TEC601 GENERAL ASSEMBLY FIGURE 2 TEC601 ENCLOSURE BACK VIEW FIGURE 3 ACCESS TO SMOKE DETECTORS FROM BOTTOM HATCHES ...

Page 5: ...ION OPERATION MANUAL PRMAN 0025 TEC601 Rev 04 01 210203 docx E OE 3 FIGURE 4 MINIMUM RECOMMENDED CLEARANCES 5 INDICATIONS CONTROLS Refer to FIGURE 1 and Table 1 Table 2 for the location and description of panel indications and controls FIGURE 5 TEC601 MEMBRANE ...

Page 6: ...isables Zone 3 and the respective Disable LED will be illuminated SILENCE BUZZER The buzzer is silenced and the respective fault LEDs will stop flashing indicating that the fault has been acknowledged The buzzer will sound again with flashing LEDs on any new fault SILENCE ALARM The sounder is silenced RESET The unit is reset and a self diagnostic is performed Should there be any faults the respect...

Page 7: ...Step 10 Switch the unit on at the back of the unit NB The cabinet is now protected When initially plugged in the panel will carry out a lamp test followed by a battery test Only the POWER ON AHU SUPPLY ON and MANUAL LEDs will remain on indicating that the unit has no fault NB The back section of the server cabinet should be closed to ensure Stat X extinguishant distribution The technician must ens...

Page 8: ... desirable to release the extinguishant then either activate the manual release call point or switch back to AUTO MANUAL mode The extinguishant release delay cycle will restart from the beginning of the set time delay During a discharge the EXTINGUISHANT RELEASED LED will flash twice per second After a discharge has taken place the EXTINGUISHANT RELEASED LED will remain on A manual reset on the TE...

Page 9: ... non volatile memory with a 100 000 read write lifespan The panel will log a total of 1 022 entries on a FIFO basis In order to extract the event logs connect a USB cable to the USB type B port provided and follow the procedure as detailed in 10 PROCEDURE FOR EXTRACTING LOGS on page 8 Button Pressed Logged Code Disable Zone 1 B1 Disable Zone 2 B2 Disable Zone 3 B3 Silence Buzzer BB Silence Alarm B...

Page 10: ...ch USB Driver inf It is best to extract the files to a folder on your PC 5 Hercules version 3 2 8 Next decide which USB port to connect your device to If your computer has USB ports on the front consider using one of those if you plan to frequently connect and disconnect the device You can use any port the next time you plug in the device Plug the TEC601 into your computer Make sure both the TEC60...

Page 11: ...nsider using one of those if you plan to frequently connect and disconnect the device You can use any port the next time you plug in the device Plug the TEC601 into your computer Make sure the TEC601 and the computer are turned on before connecting them During the driver installation select Have Disk and browse to the Technoswitch USB Driver inf file to complete the driver installation process Ope...

Page 12: ...or structural alterations have been carried out that would affect the placement location of call points or detectors If so perform a visual inspection 6 Any defects or remedial actions must be recorded in the logbook and carried out as soon as possible 7 Confirm that all monitored circuits are functional 12 1 4 ANNUAL ACTIONS 1 Perform the checks as recommended in the Daily Monthly and Quarterly s...

Page 13: ...eir date of manufacture on a new installation It is quite normal for lead acid batteries to vent hydrogen when being charged The panel is adequately ventilated to dissipate this hydrogen DO NOT seal the enclosure or install in a sealed enclosure or cavity 12 3 2 STAT X REPLACEMENT The panel has been designed so that it is easy to replace the Stat X aerosol generator after a release or after the us...

Page 14: ...tery Load Fail Battery Faulty Charger Fail Mains High Low 3 V DC 24 V DC Smoke Detectors 1x Apollo S65 Optical Smoke Detector 1x Apollo S65 Ionisation Smoke Detector Extinguishant Stat X Aerosol Generator to be ordered separately Note Compatible with Stat X only Temperature Range 5 C to 40 C Humidity 95 RH Non condensing Weight excl Stat X 10 kg Dimensions D x H x W 495 x 89 x 440 mm 14 STAT X AER...

Page 15: ...o Section 14 for guidance on the correct size Stat X unit to be used SPARES Product Code Description PCB TEC601 DIS TEC601 Display PCB PCB TEC601 MAIN TEC601 Main PCB MEM TEC601 TEC601 Membrane HAR TEC601 RC41 TEC601 Cable Harness Kit ENC EXT MCP TEC601 Spare Manual Call Point Cover 17 WARRANTY General Terms and Conditions are available from the Technoswitch website www technoswitch co za Alternat...

Page 16: ...e Road Laser Park Johannesburg PO Box 1752 Randpark Ridge South Africa 2156 CAPE TOWN T 27 0 21 948 4575 Tyger Terraces II Block 2B DJ Wood Street Bellville Business Park Cnr Mike Pienaar Blvd Voortrekker Road Bellville 7530 DURBAN T 27 0 31 266 8843 Colchester Building Essex Gardens 1 Nelson Road Westville 3629 www technoswitch co za ...