Technosoft 2018
13
iPOS4808 VX Technical Reference
CAN-Bus
Min.
Typ.
Max.
Units
Standards compliance
ISO11898, CiA-301v4.2 & 402v3.0
Bit rate
Depending on software settings
125
1000
Kbps
Bus length
1Mbps
25
m
800Kbps
50
500Kbps
100
≤ 250Kbps
250
Termination resistor
Between CAN-Hi, CAN-Lo
none on-board
Node addressing
Strapping option (AxisID0,1,2)
1 ÷ 127 (CANopen); 1-195
& 255 (TMLCAN)
-
Voltage, CAN-Hi or CAN-Lo to
GND
-26
-26
V
ESD protection
Human body model
±15
kV
Supply Output (+5V)
Min.
Typ.
Max.
Units
+5V output voltage
Current sourced = 250mA
4.8
5
5.2
V
+5V output current
600
650
mA
Short-circuit protection
NOT protected
Over-voltage protection
NOT protected
ESD protection
Human body model
±1
kV
†
Stresses beyond values listed under “absolute maximum ratings” may cause permanent damage to the device.
Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.