iPOS360x MX Technical Reference
]
IU
[
command
Voltage
Vdc
.
]
V
[
command
Voltage
65534
1
1
where Vdc
–
is the drive power supply voltage expressed in [V].
In case of
brushless
motors driven in
trapezoidal
mode, the voltage command is the voltage to
apply between 2 of the motor phases, according with Hall signals values. In this case, the
correspondence with the voltage applied in SI units i.e. [V] is:
]
IU
[
command
Voltage
Vdc
]
V
[
command
Voltage
32767
This correspondence is akso available for
DC brushed
motors which have the voltage command
internal units as the brushless motors driven in trapezoidal mode.
6.7. Voltage measurement units
The internal voltage measurement units refer to the drive V
MOT
supply voltage. The correspondence
with the supply voltage in [V] is:
]
IU
[
measured
_
Voltage
urable
VdcMaxMeas
]
V
[
measured
_
Voltage
65520
where VdcMaxMeasurable
–
is the maximum measurable DC voltage expressed in [V]. You can
read this value in the “Drive Info” dialogue, which can be opened from the “Drive Setup”.
Remark:
the voltage measurement units occur in the scaling of the over voltage and under voltage
protections and the supply voltage measurement
6.8. Time units
The internal time units are expressed in slow loop sampling periods. The correspondence with the
time in [s] is:
]
IU
[
Time
×
T
=
]
s
[
Time
where T
–
is the slow loop sampling period expressed in [s]. You can read this value in the
“Advanced” dialogue, which can be opened from the “Drive Setup”. For example, if T = 1ms, one
second = 1000 IU.
Summary of Contents for iPOS360x MX
Page 2: ......
Page 4: ......
Page 13: ... Technosoft 2014 XI iPOS360x MX Technical Reference This page is empty 1 Safety information ...
Page 69: ... Technosoft 2013 57 iPOS360x MX Technical Reference Figure 3 23 Multiple Axis CAN network ...
Page 114: ... Technosoft 2013 102 iPOS360x MX Technical Reference This page is empty ...
Page 115: ......
Page 116: ......