background image

EN7 

press and hold 

the “

CALIBRATE

” button (C2) until “

CAL

” flashes on the 

display. 
 
2) In around 20 minutes, the blinking will stop and the initial calibration is 
completed. Your CO2 monitor will return to normal display mode and will 
continue the calibration in the background. It takes 24 hours to let your 
monitor run and display the correct CO2 level. 
 

Note:

 Please wait for your CO2 monitor to complete the calibration process 

by itself. Do not press the “

CALIBRATE

” button (C2) or any other button 

during the process. 
 

Temperature 

In normal display mode, press the 

°C/°F

” button (C6) to switch between 

temperature display in °C or °F. 

To adjust the display brightness 

Press 

the “

DIMMER

” button (C1) to adjust the brightness of the display from 

High to Low to Off.   

 
Troubleshooting 
No display or functions  

Check the AC/DC adaptor is properly connected. 

 
Response time  

Ensure the air flow channels at the back of the monitor are not blocked or 
covered.  
 

CO2

  

reading 

shows “Err” 

The CO2

 

 sensor is not working properly. Unplug the AC/DC adapter (C8) 

for 10 seconds to insert it to your monitor again.  
   

Care and maintenance  

1. 

Place your monitor on a stable surface, away from sources of direct 
sunlight or excessive heat or moisture.  

Summary of Contents for WL 1030

Page 1: ...EN1 WL 1030 Instruction manual Overview ...

Page 2: ...w C1 DIMMER button C2 and CALIBRATE button C3 MEM button C4 CO2 RH SET button C5 ALARM CO2 button C6 and C F button C7 Insert DC jack to power up your item C8 AC DC power adapter C9 Connect AC plug to household power socket Main features Triple color displays of CO2 level temperature and relative humidity Non dispersive infrared NDIR gas sensor for CO2 detection Wide CO2 measuring range from 400 t...

Page 3: ...t side of your WL 1030 B1 The display will come on with the relevant temperature and relative humidity Your CO2 reading shows 150 and starts to countdown in seconds with a moving chart Relevant CO2 data will be displayed within 2 5 minutes It will continue to calibrate itself and will display the correct CO2 data within 24 hours If the AC power is interrupted the monitor does not work the display ...

Page 4: ...the CO2 digits 2000 default flash and the icon A2 appears Press the or the button to adjust the high alert level of CO2 in steps of 10 PPM The highest CO2 alert level is 5000 PPM 3 Press the CO2 RH SET button C4 again the humidity digits 35 default flash and the icon A1 appears Press the or the button to adjust the low alert level of RH in steps of 1 Lowest alert level is 20 4 Press the CO2 RH SET...

Page 5: ... Press the ALARM CO2 button C5 once to turn on the CO2 alarm When the alarm is on the CO2 sound alarm icon A5 appears on the display 2 When the measured CO2 reaches the set high alert level both the A2 and CO2 sound alarm icon A5 flash and an audible beep sound will be given continuously The beep sound will accelerate when the measured CO2 level exceeds more over the set alert level If this happen...

Page 6: ...is monitor is factory calibrated to a 400 PPM CO2 standard concentration Caution Do not manually calibrate the monitor in an environment of unknown CO2 concentration Automatic baseline calibration Your monitor is equipped with a smart chip so that it will automatically calibrate itself to reduce the drift of the CO2 sensor for long time usage It will calibrate itself automatically at the minimum C...

Page 7: ...the process Temperature In normal display mode press the C F button C6 to switch between temperature display in C or F To adjust the display brightness Press the DIMMER button C1 to adjust the brightness of the display from High to Low to Off Troubleshooting No display or functions Check the AC DC adaptor is properly connected Response time Ensure the air flow channels at the back of the monitor a...

Page 8: ...1 500 ppm Start ventilation of the room 1 500 2 000 ppm Level associated with complaints of drowsiness and poor air Ventilation recommended 2 000 5 000 ppm Level associated with headaches sleepiness and stagnant stale stuffy air Poor concentration loss of attention increased heart rate and slight nausea may also be present Ventilation strongly recommended 5 000 ppm Exposure may lead to serious oxy...

Page 9: ...nge display CO2 400 400 PPM HI 5000 PPM Temperature LO 0 C 32 F HI 50 C 122 F Relative humidity 20 20 95 95 Power supply 5V DC 1 2A adaptor Default Settings CO2 alert Low 400 High 2000 RH alert Low 35 High 70 CO2 sound alert Off Temperature C Display brightness level High Precautions The item is intended to be used only indoors Do not subject the item to excessive force or shock Do not expose the ...

Page 10: ...of duty according to the law of electrical devices This symbol means that you must dispose of electrical devices separated from the General household waste when it reaches the end of its useful life Take your item to your local waste collection point or recycling centre This applies to all countries of the European Union and to other European countries with a separate waste collection system ...

Reviews: