- New Bike: Technical service guide - rev. 4.1
Page 9.25
9.5.1.1.
Table of configuration parameters
To display the parameter values correctly, it is necessary to read them from the Low Kit,
using the function “Read from low kit”.
After making any changes to the parameters, it is necessary to write them (save them) on
the Low Kit, using the function “Write to low kit”.
Id
(Par.)
Unit
of measure
Name
Description
VISIO
Pow.
1
decimals
[Rt]
Transmission report
135
2
[Rvel]
Speed Ratio (whole part)
9
3
mA
[Im]
Minimum Braking
500
4
W
[Pmc]
Constant maximum power
200
5
in
hundredths.
[Km]
Power corrective coefficient
100
6
0.1N
[Ca]
User friction torque
13
7
°C
[Tea]
Maximum temperature on the coil
125
8
rpm user
[RPMmin] Minimum Rpm (start cut braking ramp)
30
9
type/sec
[RpmF1]
Rpm integration scale
1
10
rpm user
[RpmF2]
Rpm filter threshold
30
11
[Rvel]
Speed Ratio (decimal part)
0
12
0.1N
[D_Ca]
Delta User friction torque
8
13
-
-
Enable flag for registers at address ≥ 100
-
Summary of Contents for New Bike EXCITE Plus
Page 2: ......
Page 4: ......
Page 11: ...EXCITE New Bike Technical service guide rev 4 1 Page vii Blank page...
Page 12: ......
Page 16: ......
Page 34: ...EXCITE New Bike Technical service guide rev 4 1 Page 2 18 2 8 6 700 UNITY POWERED MODEL...
Page 44: ...EXCITE New Bike Technical service guide rev 4 1 Page 3 2 3 1 UNITY MODELS...
Page 66: ......
Page 121: ...EXCITE New Bike Technical service guide rev 4 1 Page 6 47...
Page 187: ...EXCITE New Bike Technical service guide rev 4 1 Page 7 65 Blank page...
Page 188: ......
Page 221: ...EXCITE New Bike Technical service guide rev 4 1 Page 9 27 Blank page...
Page 222: ......
Page 225: ...EXCITE New Bike Technical service guide rev 4 1 Page 10 3 Blank page...
Page 226: ......
Page 232: ...EXCITE New Bike Technical service guide rev 4 1 Page 12 2 Blank page...
Page 234: ...EXCITE New Bike Technical service guide rev 4 1 Page 13 2 Blank page...
Page 236: ......