ISOCONTROL: Service & Maintenance Manual - rev. 1.2
Pagina 6.31
6.3. THE ROM IS NOT READ OR IS READ INCORRECTLY
This error can be caused by an incorrect machine configuration, or problems with the encoder
signal.
Has the machine been
conf igured correctly ?
Are the encoder pulley s
assembled in the correct
position?
Is the weight stack cable taut?
Are the pulley s correctly wired?
Does the machine hav e two
pulley s?
Assemble the encoder
pulley in the correct
position
Adjust the tension on
the weight stack
THE ROM IS NOT
DETECTED OR
DETECTED
INCORRECTLY
NO
YES
NO
YES
NO
YES
NO
YES
A
2
3
4
Perf orm the encoder test on
both pulley s to determine
which one is not working, in
order to carry out the
remaining tests on that one
Inv ert the connection
NO
5
Conf igure the machine
correctly
1
YES
6