- VARIO: Technical service guide- Ver. 2.1
Page 6.19
6.9.
MESSAGE ON DISPLAY “THE EQUIPMENT IS LOCKED
(COM)”
This error message can be caused by loss of communication between the High Lit and Low Kit and
a 'possible interruption during SW loading/upgrade.
The error is displayed by a massage and stored in the “
Errors Log
” section.
To reinstate communications between the lower and upper assemblies:
(1)
Check that cable
CU672
is correct, using the
Test Box Excite
and replace if necessary.
(2)
Try replacing the Brake Board and the CPU/ARM Board in turn, and check whether the
communication works.
If you replace Brake Board, check that its SW version is updated, otherwise install the
last version.
Summary of Contents for EXCITE+ VARIO
Page 2: ......
Page 4: ......
Page 10: ...EXCITE VARIO Technical service guide Ver 2 1 Page vi Page blank...
Page 30: ...EXCITE VARIO Technical service guide Ver 2 1 Page 2 18 2 8 6 POWERED 700 UNITY MODEL...
Page 38: ...EXCITE VARIO Technical service guide Ver 2 1 Page 2 26 Page blank...
Page 40: ...EXCITE VARIO Technical service guide Ver 2 1 Page 3 2 3 2 UNITY BLOCK DIAGRAM...
Page 62: ...EXCITE VARIO Technical service guide Ver 2 1 Page 3 24 Page blank...
Page 66: ...EXCITE VARIO Technical service guide Ver 2 1 Page 4 4 Page blank...
Page 118: ...EXCITE VARIO Technical service guide Ver 2 1 Page 6 46 Page blank...
Page 132: ...EXCITE VARIO Technical service guide Ver 2 1 Page 8 6 Page blank...
Page 166: ...EXCITE VARIO Technical service guide Ver 2 1 Page 12 2 Blank page...
Page 168: ...EXCITE VARIO Technical service guide Ver 2 1 Page 13 2 Blank page...
Page 170: ......