- VARIO: Technical service guide- Ver. 2.1
Page 6.35
6.15.2.
HR/HS
R
ECEIVER
(C
HEST
B
ELT
)
700 models
CORRECT USE OF THE CHEST BELT: Wear the chest belt take care the area of
contact with the body is humid in order to guarantee it proper works.
THERE IS NO HR
SIGNAL
(Chest Belt)
Check if the +5Vdc are at the
input of the Receiver Board.
Are present?
ARM/CPU Board
defective.
Replace.
1
NO
YES
Check if the +5Vdc are at the
output of ARM/CPU Board.
Are present?
Receiver Board
defective.
Replace.
2
YES
NO
NO
YES
A
Check the SW and the
grounding of Receiver Board.
Problem persist?
3
Replace the connecting
cable between High Kit
and Low Kit.
YES
Check if using the Hand
Sensors the Heart Rate
detected.
OK
NO
Continued on following page ...
Summary of Contents for EXCITE+ VARIO
Page 2: ......
Page 4: ......
Page 10: ...EXCITE VARIO Technical service guide Ver 2 1 Page vi Page blank...
Page 30: ...EXCITE VARIO Technical service guide Ver 2 1 Page 2 18 2 8 6 POWERED 700 UNITY MODEL...
Page 38: ...EXCITE VARIO Technical service guide Ver 2 1 Page 2 26 Page blank...
Page 40: ...EXCITE VARIO Technical service guide Ver 2 1 Page 3 2 3 2 UNITY BLOCK DIAGRAM...
Page 62: ...EXCITE VARIO Technical service guide Ver 2 1 Page 3 24 Page blank...
Page 66: ...EXCITE VARIO Technical service guide Ver 2 1 Page 4 4 Page blank...
Page 118: ...EXCITE VARIO Technical service guide Ver 2 1 Page 6 46 Page blank...
Page 132: ...EXCITE VARIO Technical service guide Ver 2 1 Page 8 6 Page blank...
Page 166: ...EXCITE VARIO Technical service guide Ver 2 1 Page 12 2 Blank page...
Page 168: ...EXCITE VARIO Technical service guide Ver 2 1 Page 13 2 Blank page...
Page 170: ......