RUN EXCITE-2008: Service & Maintenance Manual - rev. 1.3
Page 6.4
6.1.4.
TGS
COM
T
EST
The test checks the communication with the TGS reader. The test can have two outcomes:
•
“Test Successful”:
This means that the test was completed successfully, i.e. that serial
communications on the selected port are correct.
•
“Error COM3”:
This means that the outcome of the test was negative.
The “TGS COM test” done on machine not provided with the key reader gives a fail outcome.
6.1.5.
DTV
B
OARD
TEST
It’s a command that allows to divert the serial communication, usually between the Digital TV
boardand the CPU board, on the external CSafe port.
This function wich allows to connect an external device to the Digital TV board is not used at the
moment.
Once the function has been launched it is necessary to switch off and switch on again the
machine to reinstate the correct connection.
6.1.6.
I
NVERTER
T
EST
The inverter test checks the condition of the ALE/AT UL driver. The test can have two outcomes:
•
“Test Successful, press Enter to continue”:
This means that the test was completed
successfully and the inverter is not in an error condition.
•
“Inverter Error, press Enter to continue”:
This means that the test was not completed
successfully, i.e. that the serial link is inactive and/or the inverter is in an error condition.
•
6.1.7.
U
P
D
OWN
T
EST
The UpDown test checks whether the number of pulses output by the encoder corresponds to the
values of the UpDown table stored in the low kit. During the test, the machine incline is moved
from 0 to 15% (18% on 700 and 900 model) and then back to 0. Each incline position is converted
into a number of pulses and compared with the value in the UpDown table.
Two messages appear during the test:
•
“Incline =15%”: This message appears during the upward movement, when the machine incline
reaches 15%.
•
“Incline =3%”: This message appears during the downward movement, when the machine
incline reaches 3%.
Summary of Contents for EXCITE Run 500
Page 1: ...D446 D448 D449 SERVICE MAINTENANCE MANUAL REV 1 3...
Page 2: ......
Page 4: ......
Page 32: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 2 20 Page intentionally left blank...
Page 52: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 3 20 Page intentionally left blank...
Page 59: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 4 7 Page intentionally left blank...
Page 60: ......
Page 127: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 7 19 Continued on following page...
Page 148: ......
Page 217: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 9 63 Page intentionally left blank...
Page 218: ......
Page 229: ...RUN EXCITE 2008 Service Maintenance Manual rev 1 3 Page 11 7 Page intentionally left blank...
Page 230: ......
Page 233: ......