![Technogym BIOSTRENGTH LINE Service Maintenance Manual Download Page 394](http://html1.mh-extra.com/html/technogym/biostrength-line/biostrength-line_service-maintenance-manual_1070169394.webp)
BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 7.220
7.6.8. D
ISASSEMBLING THE FRONT GUARD
Figure 7.6.8-1
1. Move the seat to position 0 so that the easy
start lever is down.
2. Shut off the equipment and unplug the power
cord from the wall socket.
For each side:
3. Remove the cap
a
of the GUARD using a
small flat screwdriver.
4. Unscrew the screw under the cap
a
using a
medium-sized Philips screwdriver.
5. Spread the sides slightly and slide out the
FRONT GUARD.
To reassemble the FRONT GUARDS, follow the
above steps in reverse order.
Reassemble the FRONT GUARD,
snapping it into the front locks
provided.