BIOSTRENGTH LINE: Service & Maintenance manual - rev. 2.1
Page 6.50
6.18. THE MACHINE DOES NOT READ THE TGS: THE RED LED
ON THE KEY READER IS NOT LIT
This problem occurs when the display does not recognize that a TGS has been inserted in the key
reader, or is unable to access the TGS. This is caused by a problem with the TGS interface
components (TLCBR and key reader and the corresponding connector cables) or by a defective
TGS. It should not concern problems with the CPU, since the initial test checks communication, and
in any case no error message means that the serial communication line between the CPU board and
TLCBR is working properly.
Perform these tests using a TGS known to work properly.
Check whether the BS-TLCBR
cable is intact
Replace the BS-TLCBR
cable
THE MACHINE
DOES NOT READ
THE TGS
NO
YES
Check whether the TGS is read if
the key reader is replaced with
another that works
Check whether the TGS is read if
the TLCBR is replaced with
another that works
Replace the key reader
Replace the TLCBR
Check or replace the
flat cable
NO
YES
NO
YES
Summary of Contents for BIOSTRENGTH LINE
Page 1: ...SERVICE MAINTENANCE MANUAL REV 2 1...
Page 2: ......
Page 4: ......
Page 16: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page xii Page intentionally left blank...
Page 88: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 2 70 Page intentionally left blank...
Page 99: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 3 11 Figure 3 2 5...
Page 122: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 4 2 Page intentionally left blank...
Page 634: ...BIOSTRENGTH LINE Service Maintenance manual rev 2 1 Page 9 26 Page intentionally left blank...
Page 645: ......