![Technische Alternative RSM610 Installation Instructions And User Manual Download Page 26](http://html1.mh-extra.com/html/technische-alternative/rsm610/rsm610_installation-instructions-and-user-manual_1069689026.webp)
26
User manual
This brief guide is aimed at the final user of the module.
For information about programming or installing the controller, separate instruction manuals are
available on our homepage (
) and on the controller's SD card.
The RSM610 control module can be used as a separate controller or as an add-on module for the
freely programmable UVR16x2 controller. Unlike the UVR16x2, however, the module does not have
an operating display screen directly on the device. Consequently, it is operated from either the
UVR16x2 (version V1.13 or higher), the CAN-MTx2 CAN monitor or the C.M.I.
The wide variety of systems means that a single instruction manual for all application scenarios is
not possible. You should therefore always seek instructions from your heating system installer.
When the module is used
in conjunction with UVR16x2
or
CAN-MTx2
, the programmer will create a
"
function overview
" in the controller for user operation. This function overview may also include the
RSM610. In the function overview, you can check all important measurements and change settings
in selected functions which are important to you as the user.
The RSM610 can also be operated via the
C.M.I.
Control and Monitoring Interface. In that case, the
"
online scheme
" is provided for operation by the user. Operation via the online scheme is essentially
the same as when using the function overview.
In this manual, we explain how you can select the function overview or online scheme and how you
can adjust the settings on your system.
Note
: Your personal system will normally vary from the examples in this manual.
LED status indicators
Status indicators of outputs 1-6
The status light can indicate a variety of sta
-
tuses by means of 3 colours
An active
Message
can be displayed by a change in a status indicator. This can be set in the
Param
-
eters menu
of the "
Message
" function.
Status indicators at controller start
Indicator light
Explanation
Steady red light
The controller is booting up (= start routine after switching on, resetting or
updating)
or
Steady orange light Hardware is initialising after booting up
Flashing green
light
After hardware initialisation, the controller waits about 30 seconds to re
-
ceive all the information necessary for a function (sensor values, network in
-
puts)
Steady green light
Normal operation of the controller