35
Room sensor RASPT
Operation mode:
The room sensor
RASPT
is a special
development of „Technische Alternative” and is provided for
installing in living rooms (reference room). It should not be
installed near to a heating source or to a window.
It is possible to change the room temperature in heating
mode in a range of approx. +/- 4°C and to select between
several modes (automatic, normal, lowered and frost protec-
tion mode).
Connection:
The
RASPT
has to be connected to the termi-
nal position T6 and sensor mass (ground).
Setting:
Operating with controller HZR65 the room sensor
must be defined as parameter “
rAS
” in automatic mode. Only
in this case the controller detects the values of the sensor.
Frost protection conditions for heating circuit
The frost protection limit is set in mode “
Stb
” (Standby) as parameter.
Factory setting: +5°C, setting range: 0
– 99 °C
Mode
Par - setting in
mode Aut
Frost protection activation of
heating-circuit pump
(decreasing the frost protection limit
)
Automatic/lowered/normal
rAS
only by room sensor T6, independent
from outdoor sensor T5
Automatic/lowered/normal
Std
by outdoor sensor T5
Automatic/lowered/normal
Unb
no frost protection
Standby on the controller
rAS
by room sensor T6
and
outdoor sensor T5
Standby on the controller
Std
by outdoor sensor T5
Standby on the controller
Unb
by outdoor sensor T5
Standby on room sensor
RASPT
rAS
only by room sensor T6, independent
from outdoor sensor T5
Standby on room sensor RAS
(KTY)
rAS
only by outdoor sensor T5