Page 58 • MN06201 ║ Issue/Rev. 0.1 (2/20)
AccuLoad IV Installation and Maintenance Manual
SA Components
10.2.
FCM Components
The FCM contains a minimum of one and a maximum of four board sets to provide up
to 18 loading arms. Each board set consists of an A4M and an A4B and optionally an
A4I module. The board sets are referred to as A, B, C and D and are mounted in the
FCM enclosure as shown below:
Figure 36.
Model SA-FCM components
For convenience, a factory wired DC distribution terminal block (shown above) is pro
-
vided in the bottom left corner of the FCM there is one DC distribution terminal block for
each of the A4M board(s) in the FCM. The input to this terminal block is factory wired to
the associated board set and provides 12 separate slots to supply 24 VDC to external
equipment such as the MMI, external meter transmitters, DC digital inputs etc.
Factory Wired
+24 VDC
Ground