Mounting systems and bracket systems for portable medical devices may be returned up to 60 days of receipt if:  

 

The product is not what was originally ordered

 

The product does not meet specifications with TECHNIMOUNT’s technical sheets according to the customer

 

The product is not compatible with the equipment on which it was to be installed

For any manufacturing defect, refer to the conditions of the Warranty Policy.

PRIOR TO 30 DAYS

 

Product must be undamaged and in its original packaging

 

The  product  return  request  must  be  provided  in  writing  and  it  must  be  approved  by  TECHNIMOUNT  prior  to 

returning the product

 

Returns will not be approved on a modified or damaged item

 

Charges may apply if damaged or missing item

 

Customer is responsible for a 10% restocking fee

PRIOR 45 DAYS

 

Product must be unused, undamaged and in its original packaging

 

The  product  return  request  must  be  provided  in  writing  and  it  must  be  approved  by  TECHNIMOUNT  prior  to 

returning the product

 

Returns will not be approved on modified or damaged item

 

Charges may apply if damaged or missing items 

 

Customer is responsible for a 25% restocking fee

PRIOR 60 DAYS

 

Product must be unused, undamaged and in its original packaging

 

The  product  return  request  must  be  provided  in  writing  and  it  must  be  approved  by  TECHNIMOUNT  prior  to 

returning the product

 

Returns will not be approved on a modified or damaged item

 

Charges may apply if damaged or missing items 

 

Customer is responsible for a 30% restocking fee

RETURN AUTHORIZATION

TECHNIMOUNT’s customer service department is responsible for approving any merchandise return and will provide 

a  Return  Merchandise  Authorization  (RMA)  number  to  be  printed  on  any  returned  merchandise.  TECHNIMOUNT 

reserves the right to charge shipping and restocking fees on returned items. SPECIAL, MODIFIED, OR DISCONTINUED 

ITEMS NOT SUBJECT TO RETURN.

Summary of Contents for PRO 77 Series

Page 1: ...BRACKET PRO SERIE 77 USER GUIDE ...

Page 2: ... relationship with Laerdal Laerdal does not promote or sell Technimount products In order to ensure continuous improvements to our products and services we invite you to communicate your comments to our Customer Service Department at customerservice technimount com LEGAL NOTICE Technologies CGC Inc or Technimount E M S Holding Inc or its affiliates are not expressly associated with the marketing d...

Page 3: ...our Technimount product its components or for any technical questions during the installation or maintenance processes please send an email to techsupport technimount com Please have the serial number of your Technimount product available as shown in the figure below when calling Technimount Technical Support Include the serial number in all written communications SERIAL NUMBER LOCATION CONTACT IN...

Page 4: ...ON GUIDE 15 Removing the Packaging for Installation 15 Tools Required for Installation 15 Identification of Components 16 Bottom Support Block 16 Hardware Kit 16 Installation of the Bracket onto the Laerdal Compact Suction Unit 4 17 Installation of the Canister into the Bracket 19 Removing the Canister from the Bracket 20 MAINTENANCE GUIDE 21 Cleaning 21 Cleaning Process 21 Removal of Iodine Compo...

Page 5: ...E OF CONTENTS RETURN POLICY 28 Return Policy 28 Prior to 30 Days 28 Prior 45 Days 28 Prior 60 Days 28 Return Authorization 28 Damaged Merchandise 29 Claim Process 29 Required Information 29 Findings and Conclusion 29 Questions about our Policy 29 ...

Page 6: ...s 6 BP77 UG 202108 01 www technimount com INTRODUCTION SYMBOLS AND DEFINITIONS SYMBOL DESCRIPTION Warning and Caution special attention is required Consult accompanying documents Safe working load symbol and Load balance symbol ...

Page 7: ...serious injury It may also describe potential serious adverse reactions and safety hazards Caution Alerts the reader of a potentially hazardous situation which if not avoided may result in minor or moderate injury to the user or patient or damage to the equipment or other property This includes special care necessary for the safe and effective use of the device to avoid damage that may occur as a ...

Page 8: ...Contents 8 BP77 UG 202108 01 www technimount com PRODUCT ILLUSTRATION BRACKET PRO SERIE 77 Front View INTRODUCTION Strap to Secure 800ml Canister Bracket for 800ml Canister High Density Aluminum with Black Anodized Finish ...

Page 9: ...1 9 Return to Table of Contents PRODUCT ILLUSTRATION CONTINUED BRACKET PRO SERIE 77 SUITE Back View INTRODUCTION Bottom Support Block to Secure Medical Device Anti Rotation Micro Disc for Installation on Vertical and Wall Mounting Systems ...

Page 10: ...and install medical equipment owned by the customer on an incubator transport stretcher manufactured by Stryker and involving or not a Dräger or other incubator brand The purchase and use of products designed by Technimount are subject to this limitation of liability clause It is important to understand that as Technimount is not the manufacturer of the Stryker stretcher or other brand nor the man...

Page 11: ...t Options Anti Rotation Micro Disc Transportation Compatibility System Compatible with Technimount s Safety MD Transporter vertical Vertical Mounting System Micro Base Features Access to all Medical Device Monitors Connectors and Accessories Rubber Pads Protecting the Bracket when Placed on a Surface Rubber Cushions Inside the Bracket to Protect Medical Device Anti Rotation Micro Disc for installa...

Page 12: ... fall during transport and may cause injury to the patient or operator and or damage to the product 9 Do not allow untrained staff to assist in the operation of the mounting system Untrained technicians staff can cause injury to the patient or themselves 9 Do not place additional equipment or items onto the bracket or mounts other than approved Technimount or components as this could damage the pr...

Page 13: ...ossibly causing premature corrosion of critical components 9 When ordering it is important to identify on which mounting system you need to mount the bracket on as there are different systems for different applications ground 9 A maintenance program should be established for all Technimount equipment Preventive maintenance may need to be performed more frequently based on the level of use of the p...

Page 14: ...ount com WARNING The end user and administrator are responsible to validate regulations and standards for safety in their region in order to comply with applicable safety regulations Technimount is not responsible to inform the end user and or administrator of applicable legislation for safety in their area LEGAL NOTICE The purchase and use of products designed by Technimount are subject to this l...

Page 15: ...if needed TOOLS REQUIRED FOR INSTALLATION Below are the basic tools required for installation Other tools may also be required If you have any questions regarding the installation or need assistance please contact our Technical Support team at techsupport technimount com 9 Phillips Screwdriver NOTE 9 Electrical tools are not recommended as there is a potential risk of damage to the threads 9 Techn...

Page 16: ...xide Stainless Steel bottom support block is designed to hold Laerdal Compact Suction Unit 4 by securing its base HARDWARE KIT Thefollowinghardwareisprovidedfortheinstallation of the Bracket Pro Serie 77 9 Two 2 Black Oxide Stainless Steel Flat Head Phillips Screws 10 32 x 1 2 9 Two 2 Black Oxide Stainless Steel Flat Head Phillips Screws 10 32 x 3 8 ...

Page 17: ...t 4 from Laerdal 2 Locate the medical device and bottom support block of the main assembly 3 Align the bottom of the medical device with the bottom support block 4 Install the top part of the bracket above the medical device align rear vertical rods with the mounting holes INSTALLATION GUIDE INSTALLATION OF THE BRACKET ONTO THE LAERDAL COMPACT SUCTION UNIT 4 ...

Page 18: ...he two 2 screws well 8 Align the screws and screw holes at the back of the main assembly 9 Install the two 2 Black Oxide Stainless Steel Flat Head Phillips Screws 10 32 x 3 8 on the main assembly NOTE Put a few drops of medium strength thread locking adhesive blue Loctite 242 on each screw before installation to prevent the screws from loosening during normal use 10 Tighten the two 2 screws well C...

Page 19: ...KET 1 Keep the strap up 2 Install the 800ml canister into the main assembly 3 Verify that the 800ml canister is properly installed in the main assembly 4 Close the strap on the canister lid and lock it 5 Laerdal Compact Suction Unit 4 is ready for transport once properly inserted into its bracket and the stretcher mounting system ...

Page 20: ...echnimount com REMOVING THE CANISTER FROM THE BRACKET 1 To remove the 800ml canister from the bracket lift the strap on the canister lid 2 Raise the strap completely 3 Remove the canister from the bracket by lifting it upwards to release it OPERATION GUIDE ...

Page 21: ...scoloration from continuous washing however degradation of the product s performance or functionality will not be affected due to power washing if cleaning instructions are properly followed The material used to manufacture the bracket is high grade aluminum it is very durable and resistant to corrosion however high levels of sodium or a high concentration of sodium or acid may prematurely corrode...

Page 22: ... the product we recommend sanding the affected surface to remove the rust and then using the cleaning method presented in this guide once the rust is removed To clean the stained area use a solution of 1 4 Tablespoon of Sodium Thiosulfate in 1 pint 5 litre of warm water to clean the stained area Clean as soon as possible after staining occurs If stains are not immediately removed allow solution to...

Page 23: ...erform these inspections please contact your Technical Support Team at techsupport technimount com Check each routine and replace damaged or worn out parts if necessary Follow timetable below for maintenance either in months M or hours H in accordance with your Service s current maintenance practices and protocols ITEM ROUTINE 1 M OR 2 H 3 M OR 6 H 6 M OR 12 H 12 M OR 24 H Bracket 9 Inspect the br...

Page 24: ...Return to Table of Contents 24 BP77 UG 202108 01 www technimount com MAINTENANCE GUIDE INSPECTION AND MAINTENANCE RECORD PREVENTIVE MAINTENANCE PERFORMED BY DATE TIME ...

Page 25: ...www technimount com BP77 UG 202108 01 25 Return to Table of Contents MAINTENANCE GUIDE TRAINING RECORD DATE TRAINING METHOD TRAINEE NAME BASIC TRAINING TRAINING UPDATE ...

Page 26: ...e may not be individually available for purchase Please call Technimount Customer Service 1 888 639 2758 or at customerservice technimount com for availability and pricing DESCRIPTION PART NUMBER Bracket Pro Serie 77 770 10 LASP Two 2 Black Oxide Stainless Steel Flat Head Phillips Screws 10 32 x 1 2 TCM VF 999 114 Two 2 Black Oxide Stainless Steel Flat Head Phillips Screws 10 32 x 3 8 TCM VR 999 0...

Page 27: ...aced after the Warranty Period has expired the Warranty Period for the repair or replacement will expire three 3 months after the date of repair or replacement LIMITED RESPONSIBILITY AND WARRANTY The Limited Warranty does not apply to normal wear that should result from normal use It does not apply when the Hardware or any component is opened disassembled or repaired by someone not authorized by T...

Page 28: ... 45 DAYS Product must be unused undamaged and in its original packaging The product return request must be provided in writing and it must be approved by TECHNIMOUNT prior to returning the product Returns will not be approved on modified or damaged item Charges may apply if damaged or missing items Customer is responsible for a 25 restocking fee PRIOR 60 DAYS Product must be unused undamaged and i...

Page 29: ...the RMA form online at https www technimount com service support service support overview REQUIRED INFORMATION Serial number Invoice number Identification of the issue Upload the pictures of the issue Submit the form A confirmation of the receipt of the claim will be sent to you within 2 business days If you have not received a confirmation email by then please contact techsupport technimount com ...

Page 30: ... matters most Technimount E M S Holding Inc 3770 Jean Marchand Street Suite 100 C Quebec QC G2C 1Y6 Canada T 1 888 639 2758 F 1 855 339 6351 technimount com info technimount com 2021 Technimount E M S Holding Inc All Rights Reserved Printed in Canada ...

Reviews: