Return To Table of Contents

22

BP60-SD UG 202109-01

www.technimount.com

DESCRIPTION

PART NUMBER

Bracket Pro Serie 60-SD

700-12-HMDC

Floor Mount

554-20-AB-FL

Standard Surface Base

100-20-UN

Safety Arm System 

Several Models Available, 

refer to Customer Service

WARNING

Do not modify any components of this system.  Modifying the product can cause unpredictable operation resulting in 

injury to the patient or operator. 

NOTE

Technimount reserves the right to change Part Numbers and Products without notice. Please refer to Customer Service 

to ensure product part number availability.

For any replacement parts or for repair, please contact Technical Support at 

[email protected]

Part Numbers

 KITS AND OTHER OPTIONS

Summary of Contents for PRO 60-SD Series

Page 1: ...BRACKET PRO SERIE 60 SD USER GUIDE EMS TM ...

Page 2: ...the written permission of Technimount or its affiliate companies Trademark Attributions Bracket Pro Serie Technimount EMS are registered trademarks of Technologies CGC Inc Hamilton T1 is a registered trademark of Hamilton Medical Technimount does not have any commerical relationship with Hamilton Medical Hamilton Medical does not promote or sell Technimount products In order to ensure continuous i...

Page 3: ...1 855 339 6351 NOTE For any issues with your Technimount product its components or for any technical questions during the installation or maintenance please send an email to techsupport technimount com Please have the serial number of your Technimount product available as shown in the figure below when calling Technimount Technical Support Include the serial number in all written communications SE...

Page 4: ...on T1 Ventilator 17 General Operating Guidelines for the Safety Arm System 19 Operating the Bracket on the Safety Arm System 20 Installing the Bracket onto the Standard Surface Base 20 Rotating the Bracket on the Standard Surface Base 20 Removing the Bracket from the Standard Surface Base 21 PART NUMBERS 22 Kits and Other Options 22 MAINTENANCE GUIDE 23 Cleaning 23 Cleaning process 23 Removal of i...

Page 5: ...unt com BP60 SD UG 202109 01 5 Table of Contents Return Authorization 30 Damaged Merchandise 31 Claim Process 31 Required Information 31 Findings and Conclusion 31 Questions about our Policy 31 SAE CERTIFICATION 32 ...

Page 6: ...0 SD UG 202109 01 www technimount com Introduction SYMBOLS AND DEFINITIONS SYMBOL DESCRIPTION Warning and Caution special attention is required Consult accompanying documents Safe working load symbol and Load balance symbol Pinch Point ...

Page 7: ... serious injury It may also describe potential serious adverse reactions and safety hazards Caution Alerts the reader of a potentially hazardous situation which if not avoided may result in minor or moderate injury to the user or patient or damage to the equipment or other property This includes special care necessary for the safe and effective use of the device to avoid damage that may occur as a...

Page 8: ...l feet to protect when placed on the floor or ground 2 Red Quick Release Mechanisms on each side to lower the arms to give access to the back of the medical device for maintenance purposes Device retained on main assembly with 2 upper arm locks and lateral blockers Lateral blockers on each side to retain the medical device onto the main assembly ...

Page 9: ...CONTINUED BRACKET PRO SERIE 60 SD CONTINUED Back View Introduction Standard Bottom Disc compatible with Technimount s Standard Surface Base Safety Arm System and Floor Mount High density aluminum with silver anodized finish Rubber cushions to protect the medical device while inside the bracket ...

Page 10: ...nd hospital environments When used in emergency vehicles with a cot stretcher the Bracket Pro Serie 60 SD can be positioned on Technimount s Safety Arm System Standard Surface Base and Floor Mount These solutions provide a higher flexibility for different EMS CCT protocols and applications INTENDED USE OF THE PRODUCT The Bracket Pro Serie 60 SD is a mounting solution to securely transport the Hami...

Page 11: ...unt com BP60 SD UG 202109 01 11 Return To Table of Contents Introduction POSSIBLE MOUNTING OPTIONS FOR THE BRACKET PRO SERIE 60 SD Safety Arm System Floor Mount Air Ambulance Standard Surface Base Wall Mount System ...

Page 12: ...bly with 2 upper arms with Red Quick Release Mechanisms and lateral blockers Attachment Options Standard Bottom Disc Transportation Compatibility System Compatible with Technimount s Standard Surface Base Safety Arm System For Stryker Cots PowerPro XT and Mx Pro Floor Mount Flight Features Robust Mounting Solution for EMS CCT ALS Transport No Screw or Attatchment into the Housing of the Medical De...

Page 13: ...nsport and may cause injury to the patient or operator and or damage to the product 9 Do not allow untrained staff to assist in the operation of the mounting system Untrained technicians staff can cause injury to the patient or themselves 9 Do not place additional equipment or items onto the bracket or mounts other than approved Technimount or components as this could damage the product and may re...

Page 14: ...sibly causing premature corrosion of critical components 9 When ordering it is important to identify on which mounting system you need to mount the bracket on as there are different systems for different applications ground 9 A maintenance program should be established for all Technimount equipment Preventive maintenance may need to be performed more frequently based on the level of use of the pro...

Page 15: ...tomerservice technimount com Technimount E M S Holding Inc C O Regulatory Affairs 3770 Jean Marchand Street Suit 100 C Quebec QC G2C 1Y6 Canada T 1 888 639 2758 F 1 855 339 6351 technimount com info technimount com WARNING The end user and administrator are responsible to validate regulations and standards for safety in their region in order to comply with applicable safety regulations Technimount...

Page 16: ...d for installation 2 Ensure that all shipping and packaging materials have been properly removed from the product s prior to installation 3 Identify all of the product components and hardware prior to starting the installation 4 The bracket must work properly before being put into service 5 Refer to the identification of components at the beginning of this user guide if needed ...

Page 17: ...nstalled on the Hamilton T1 Ventilator 2 Place bracket on a stable and large surface 3 Pull the two 2 Red Quick Release Mechanisms outwards on each side of the bracket to unlock the arms 4 Gently lower the bracket all the way down onto its back Installation Guide INSTALLATION OF THE BRACKET ONTO THE HAMILTON T1 VENTILATOR ...

Page 18: ...se the arms towards the front of the medical device to close and lock the arms into upper position 7 Release the Red Quick Release Mechanisms WARNING Ensure both arms are securely locked into upper position prior to transport or mobilizing with the equipment If incorrectly locked it could cause injury to the patient or operator and damage to the equipment 8 The medical device and bracket are now r...

Page 19: ...ded while the patient is on the cot stretcher 9 Use the Safety Arm System only as described in its user guide 9 Read all the labels and instructions on the product before using the Safety Arm System 9 Always inspect the Clamp Block Safety Pin Lock Pin and Standard Surface Base before every use 9 Installing or removing the Safety Arm System requires a minimum of one 1 trained operator 9 Do not remo...

Page 20: ...ontally from the front of the base 3 Ensure the bracket is locked securely in the Standard Surface Base before manipulating the device or transporting the stretcher ROTATING THE BRACKET ON THE STANDARD SURFACE BASE 1 To rotate the medical device 360 turn the bracket inside the Standard Surface Base clockwise or counter clockwise to use the device in the desired position OPERATING THE BRACKET ON TH...

Page 21: ...ACKET FROM THE STANDARD SURFACE BASE 1 To remove the bracket from the Safety Arm System press the Red Quick Release Mechanism located on the front Standard Surface Base 2 While holding the Red Quick Release Mechanism slide outwards horizontally to remove from the Standard Surface Base Hold the ventilator from the middle of the unit to gently remove from the base ...

Page 22: ... WARNING Do not modify any components of this system Modifying the product can cause unpredictable operation resulting in injury to the patient or operator NOTE Technimount reserves the right to change Part Numbers and Products without notice Please refer to Customer Service to ensure product part number availability For any replacement parts or for repair please contact Technical Support at techs...

Page 23: ...or discoloration from continuous washing however degradation of the product s performance or functionality will not be affected due to power washing if cleaning instructions are properly followed The material used to manufacture the bracket is high grade aluminum it is very durable and resistant to corrosion however high levels of sodium or a high concentration of sodium or acid may prematurely co...

Page 24: ...f the product we recommend sanding the affected surface to remove the rust and then using the cleaning method presented in this guide once the rust is removed To clean the stained area use a solution of 1 4 Tablespoon of Sodium Thiosulfate in 1 pint 5 litre of warm water to clean the stained area Clean as soon as possible after staining occurs If stains are not immediately removed allow solution t...

Page 25: ...ch routine and replace damaged or worn out parts if necessary Follow timetable below for maintenance either in months M or hours H in accordance with your Service s current maintenance practices and protocols ITEM ROUTINE 1 M OR 2 H 3 M OR 6 H 6 M OR 12 H 12 M OR 24 H Bracket 9 Inspect Bracket Inspect the screws of the bracket Inspect the bottom screw that tightens into the medical device Ensure b...

Page 26: ...Return To Table of Contents 26 BP60 SD UG 202109 01 www technimount com Maintenance Guide INSPECTION AND MAINTENANCE RECORD PREVENTIVE MAINTENANCE PERFORMED BY DATE TIME ...

Page 27: ...chnimount com BP60 SD UG 202109 01 27 Return To Table of Contents Maintenance Guide TRAINING RECORD TRAINING DATE TRAINING METHOD USER GUIDE IN SERVICE IN CLASS ETC TRAINEE NAME BASIC TRAINING TRAINING UPDATE ...

Page 28: ...or purchase Some of the parts identified on the assembly drawing parts in this user guide may not be individually available for purchase Please call Technimount Customer Service 1 888 639 2758 or customerservice technimount com for availability and pricing DESCRIPTION PART NUMBER Bracket Pro Serie 60 SD 700 12 HMSD Standard Bottom Disc 926 00 SS Acetal Feet TCM 032 082 ...

Page 29: ...placed after the Warranty Period has expired the Warranty Period for the repair or replacement will expire three 3 months after the date of repair or replacement LIMITED RESPONSIBILITY AND WARRANTY The Limited Warranty does not apply to normal wear that should result from normal use It does not apply when the Hardware or any component is opened disassembled or repaired by someone not authorized by...

Page 30: ...R 45 DAYS Product must be unused undamaged and in its original packaging The product return request must be provided in writing and it must be approved by TECHNIMOUNT prior to returning the product Returns will not be approved on modified or damaged item Charges may apply if damaged or missing items Customer is responsible for a 25 restocking fee PRIOR 60 DAYS Product must be unused undamaged and ...

Page 31: ...n the RMA form online at https www technimount com service support service support overview REQUIRED INFORMATION Serial number Invoice number Identification of the issue Upload the pictures of the issue Submit the form A confirmation of the receipt of the claim will be sent to you within 2 business days If you have not received a confirmation email by then please contact techsupport technimount co...

Page 32: ...Return To Table of Contents 32 BP60 SD UG 202109 01 www technimount com SAE Certification ...

Page 33: ...www technimount com BP60 SD UG 202109 01 33 Return To Table of Contents ...

Page 34: ...e it matters most Technimount E M S Holding Inc 3770 Jean Marchand Street Suite 100 C Quebec QC G2C 1Y6 Canada T 1 888 639 2758 F 1 855 339 6351 technimount com info technimount com 2021 Technimount E M S Holding Inc All Rights Reserved Printed in Canada ...

Reviews: