Introduction

PURPOSE OF THE DOCUMENT

This User Guide is designed to assist you with the installation, operation and maintenance of the Technimount Bracket 

Pro Serie 76 for the Tempus Pro monitor from Philips. 

PRODUCT DESCRIPTION

The Bracket Pro Serie

®

 76 mounting system is the only universal solution to mount the Tempus Pro monitor from 

Philips in different applications such as, on surface, floor, cot/stretcher and wall systems. It can fit any ground and air 

ambulance configurations in North American and European markets. It is designed to securely support and transport 

the Tempus Pro monitor in pre-hospital environments. When used in emergency vehicles with a cot/stretcher, the 

Bracket Pro Serie

®

 76 can be positioned on Technimount’s Safety Arm System, on a Standard Surface Base, on a 

Safety MD Transporter or with Technimount’s Floor Mount or Wall Mount Systems. These solutions provide a higher 

flexibility for different EMS protocols and applications. 

This mounting system is compatible with all of Technimount’s products. 

INTENDED USE OF THE PRODUCT

The Bracket Pro Serie

®

 76 is a mounting solution to securely transport the Philips Tempus Pro monitor during EMS 

transport. It is designed to be installed on the equipment as described in this user guide. This equipment is for crew 

who has received the appropriate training necessary to operate the equipment in the field according to its intended 

use as outlined in this user guide. Please read this User Guide thoroughly before using this equipment. To ensure the 

safe operation of this equipment, it is recommended to train staff prior to use.

Summary of Contents for BRACKET PRO 76 Series

Page 1: ...BRACKET PRO SERIE 76 USER GUIDE EMS TM ...

Page 2: ...or translated into any language in any form or by any means without the written permission of Technimount System or its affiliate companies Trademark Attributions Bracket Pro Serie Technimount EMS are registered trademark of Technologies CGC Inc Tempus Pro is a registered trademarks from Philips In order to ensure continuous improvements to our products and services we invite you to communicate yo...

Page 3: ...351 NOTE For any issues with your Technimount product its components or for any technical questions during the installation or maintenance please send an Email to techsupport technimount com Please have the serial number of your Technimount product available as shown in the figure below when calling Technimount Customer Service or Technical Support Include the serial number in all written communic...

Page 4: ...nitor with smart mount 19 OPERATION GUIDE 23 General Operating Guidelines for the Safety MD Transporter 23 Operating the Bracket on the Safety MD Transporter 24 Installing the Bracket onto the Safety MD Transporter 24 Rotating the Bracket on the Safety MD Transporter 25 Removing the Bracket with the Medical Device from the Safety MD Transporter 26 General Operating Guidelines for the Safety Arm Sy...

Page 5: ...ecord 35 Replacement Parts 36 WARRANTY 37 Warranty Policy 37 Return Policy 37 Prior to 30 Days 37 Prior to 45 Days 38 Prior to 60 Days 38 Return Authorization 38 Damaged Merchandise 38 International Warranty Clause 38 Claim Process 39 Required Information 39 Findings and Conclusion 39 SAE CERTIFICATION 40 ...

Page 6: ...cot stretcher the Bracket Pro Serie 76 can be positioned on Technimount s Safety Arm System on a Standard Surface Base on a Safety MD Transporter or with Technimount s Floor Mount or Wall Mount Systems These solutions provide a higher flexibility for different EMS protocols and applications This mounting system is compatible with all of Technimount s products INTENDED USE OF THE PRODUCT The Bracke...

Page 7: ...BP76 UG 202110 01 7 Return To Table of Contents Introduction POSSIBLE MOUNTING OPTIONS FOR THE BRACKET PRO SERIE 76 Safety MD Transporter Wall Mount System Ground Ambulance in Europe Safety Arm System Standard Surface Base ...

Page 8: ...76 UG 202110 01 www technimount com Introduction SYMBOLS AND DEFINITIONS SYMBOL DESCRIPTION Warning and Caution special attention is required Consult accompanying documents Safe working load symbol and Load balance symbol Pinch Point ...

Page 9: ...serious injury It may also describe potential serious adverse reactions and safety hazards Caution Alerts the reader of a potentially hazardous situation which if not avoided may result in minor or moderate injury to the user or patient or damage to the equipment or other property This includes special care necessary for the safe and effective use of the device to avoid damage that may occur as a ...

Page 10: ...Front View Introduction Standard Bottom Disc compatible with all of Technimount s mounting solutions Made from high density aluminum with black anodized finish Acetal feet to protect the Standard Bottom Disc and Tempus Pro when placed on the ground Main assembly is retained to the Tempus Pro with locking blocks ...

Page 11: ...E 76 CONTINUED Back View Introduction Anti Rotation Micro Disc is used for vertical support on different wall or arm systems Rubber pads to protect the medical device from scratches Technimount molded polyurethane transport handle Main assembly is attached to the Tempus Pro with a quick release and locking mechanism ...

Page 12: ...ing Discs Standard Bottom Disc Anti Rotation Micro Disc Transportation Compatibility System Compatible with Technimount s Standard Surface Base Safety Arm System for Stryker Cots PowerPro XT and Mx Pro Floor Mount Platform Flight Wall Mount System Safety MD Transporter Features Access to Printer and Connectors and Accessories No Screws Attached to the Medical Device Red Quick Release to Easily Ins...

Page 13: ...vice customerservice technimount com Technimount E M S Holding Inc C O Regulatory Affairs 3770 Jean Marchand Street Suite 100 C Quebec QC G2C 1Y6 Canada T 1 888 639 2758 F 1 855 339 6351 technimount com info technimount com WARNING End User Administrator is responsible to validate regulations and standards for safety in their region in order to comply with applicable safety regulations Technimount...

Page 14: ...rained staff to assist in the operation of the mounting system Untrained technicians staff can cause injury to the patient or themselves 9 Do not place additional equipment or items onto the Bracket or mounts other than approved Technimount Systems or components as this could damage the product and may result in injury to the patient or operator 9 Operators must be able to able to safely lift the ...

Page 15: ...ausing premature corrosion of critical components 9 When ordering it is important to identify on which mounting system you need to mount the bracket on as their are different systems for different EMS applications e g EMS ground or air mounting systems 9 A maintenance program should be established for all Technimount equipment Preventive maintenance may need to be performed more frequently based o...

Page 16: ... must work properly before being put into service 5 Refer to the identification of components at the beginning of this user guide if needed TOOLS REQUIRED FOR INSTALLATION Below are the basic tools required for installation If you have any questions regarding the installation or need assistance please contact our Technical Support team at techsupport technimount com 9 Philips Screwdriver NOTE 9 El...

Page 17: ...stalled on the Philips Tempus Pro monitor 2 To install the Tempus Pro monitor pull the Red Quick Release Mechanism and raise the top part until it locks into the top position 3 Align the Tempus Pro in front of the bracket while it is still raised Installation Guide INSTALLATION OF THE BRACKET ONTO TEMPUS PRO MONITOR ...

Page 18: ...LLATION OF THE BRACKET ONTO THE TEMPUS PRO MONITOR CONTINUED 4 Install the Tempus Pro into the main assembly 5 Push on the top of the bracket and lower the top part until it locks into the bottom position 6 The Tempus Pro monitor is ready for EMS Transport Installation Guide ...

Page 19: ...nitor 2 To install the Tempus Pro Smart Mount monitor pull the Red Quick Release Mechanism and raise the top part until it locks into the top position 3 Locate your Tempus Pro Smart Mount 4 Align screw holes 5 Install the four Black Oxide Flat Head Philips Screws 10 12 X 5 8 in Installation Guide INSTALLATION OF THE BRACKET ONTO TEMPUS PRO MONITOR WITH SMART MOUNT ...

Page 20: ...F THE BRACKET ONTO THE TEMPUS PRO MONITOR WITH SMART MOUNT CONTINUED 6 Tighten all four screws 7 Install the Tempus Pro monitor onto the Smart Mount as described in its user guide 8 Align screw holes 9 Install both Black Oxide Flat Head Philips Screws 10 32 X 5 8 in Installation Guide ...

Page 21: ...ble of Contents Return To Table of Contents INSTALLATION OF THE BRACKET ONTO THE TEMPUS PRO MONITOR WITH SMART MOUNT CONTINUED Installation Guide 10 Tighten both screws 11 Install the Tempus Pro monitor onto the Smart Mount as described in its user manual ...

Page 22: ...ontents INSTALLATION OF THE BRACKET ONTO THE TEMPUS PRO MONITOR WITH SMART MOUNT CONTINUED Installation Guide 12 Push on the top of the bracket and lower the top part until it locks into the bottom position 13 The Tempus Pro Smart Mount is ready for EMS transport ...

Page 23: ...ES FOR THE SAFETY MD TRANSPORTER 9 Use the Safety MD Transporter only as described in the User Guide 9 Read all the labels and instructions on the product before using the Safety MD Transporter 9 Always inspect the Micro Base and the Safety MD Transporter for any issue or damage before every use 9 Installing or removing the Safety MD Transporter requires a minimum of one 1 trained operator 9 Do no...

Page 24: ...n the back can be inserted into the Micro Base located on the Safety MD Transporter 2 Ensure that your bracket has an Anti Rotation Micro Disc on the back to install the medical device onto the Safety MD Transporter 3 While using both hands slowly insert the Anti Rotation Micro Disc located on the back of the bracket into the Micro Base WARNING 9 Ensure that the bracket is securely locked into the...

Page 25: ...RANSPORTER CONTINUED INSTALLING THE BRACKET ONTO THE SAFETY MD TRANSPORTER CONTINUED Operation Guide 4 A Bracket Pro Serie 76 installed on the Safety MD Transporter ROTATING THE BRACKET ON THE SAFETY MD TRANSPORTER 1 To rotate the medical device 360 turn the Safety MD Transporter clockwise or counter clockwise ...

Page 26: ...ONTINUED REMOVING THE BRACKET WITH THE MEDICAL DEVICE FROM THE SAFETY MD TRANSPORTER 1 To remove the bracket from the Safety MD Transporter press the Red Quick Release Mechanism located on the back Micro Base 2 While holding the Red Quick Release Mechanism lift the bracket upwards until removed and release the Red Quick Release Mechanism ...

Page 27: ...m of one 1 trained operator 9 Do not remove the Safety Arm System or device from the system while moving with the cot stretcher 9 Stay with the patient and control the Safety Arm System and device during transport at all times GENERAL OPERATING GUIDELINES FOR THE SAFETY ARM SYSTEM Operation Guide CAUTION 9 Never let a patient grab manipulate or hold the Safety Arm System the Surface Base or bracke...

Page 28: ...installed Wall Mount Floor Mount Safety Arm System etc 3 To insert the bracket into the Standard Surface Base slide into the base horizontally from the front of the base 4 Ensure the bracket is locked securely in the Standard Surface Base before manipulating the device or transporting the stretcher ROTATING THE BRACKET ON THE STANDARD SURFACE BASE 1 To rotate the medical device 360 turn the bracke...

Page 29: ...CKET FROM THE STANDARD SURFACE BASE 1 To remove the bracket from the Safety Arm System press the Red Quick Release Mechanism located on the front of the Standard Surface Base 2 While holding the Red Quick Release Mechanism slide outwards horizontally to remove from the base 3 Hold the Tempus Pro monitor from the middle of the unit to gently remove from the base ...

Page 30: ...odels Available refer to Customer Service WARNING Do not modify any components of these system Modifying the products can cause unpredictable operation resulting in injury to the patient or operator NOTE Technimount reserves the right to change Part Numbers and Products without notice Please refer to Customer Service to ensure product part number availability For any replacement parts or for repai...

Page 31: ...ower washer can accelerate removal of contaminants collected during the use of the product 9 Rinse with clean water 9 Towel dry all components 9 Allow all other components to air dry 9 Avoid over saturation and ensure that the product does not stay wet longer than the cleaner manufacturer s guidelines for proper disinfecting WARNING 9 When cleaning always use appropriate personal protection equipm...

Page 32: ...ervice WARNING 9 Failure to properly clean contaminated parts or components will increase the risk of exposure to blood borne pathogens and may cause injury to the patient or the operator PREVENTIVE MAINTENANCE A preventive and regular maintenance program should be established for all Technimount equipment Preventive maintenance may be required more frequently based on the usage level of the produ...

Page 33: ...e damaged or worn out parts if necessary Follow timetable below for maintenance either in months M or hours H in accordance with your Service s current maintenance practices and protocols ITEM ROUTINE 1 M OR 2 H 3 M OR 6 H 6 M OR 12 H 12 M OR 24 H Bracket 9 Inspect Bracket Inspect the screws Inspect the Red Quick Release Mechansim Ensure it is working properly and there are no particles obstacles ...

Page 34: ...Return To Table of Contents 34 BP76 UG 202110 01 www technimount com Maintenance Guide INSPECTION AND MAINTENANCE RECORD PREVENTIVE MAINTENANCE PERFORMED BY DATE TIME ...

Page 35: ...echnimount com BP76 UG 202110 01 35 Return To Table of Contents Maintenance Guide TRAINING RECORD TRAINING DATE TRAINING METHOD USER GUIDE IN SERVICE IN CLASS ETC TRAINEE NAME BASIC TRAINING TRAINING UPDATE ...

Page 36: ...ilver Anodized Locking Assembly Block Without Bag Kit Includes Protection Rubber Locking Assembly Block and 2 Phillips Stainless Steel Pan Head Screws with Nylon Patch 10 32 X 1 2 in TCM 044 014 Black Anodized Locking Assembly Block With Bag Kit Includes Protection Rubber Locking Assembly Block and 2 Phillips Stainless Steel Pan Head Screws with Nylon Patch 10 32 X 1 2 in TCM 044 019 Screw Kit for...

Page 37: ...replaced after the Warranty Period has expired the Warranty Period for the repair or replacement will expire three 3 months after the date of repair or replacement LIMITED RESPONSIBILITY AND WARRANTY The Limited Warranty does not apply to normal wear that should result from normal use It does not apply when the Hardware or any component is opened disassembled or repaired by someone not authorized ...

Page 38: ...YS Product must be unused undamaged and in its original packaging The product return request must be provided in writing and it must be approved by TECHNIMOUNT SYSTEM prior to returning the product Returns will not be approved on modified or damaged item Charges may apply if damaged or missing items Customer is responsible for a 25 restocking fee PRIOR TO 60 DAYS Product must be unused undamaged a...

Page 39: ...e RMA form online at https www technimount com service support service support overview REQUIRED INFORMATION Serial number Invoice number Identification of the issue Upload the pictures of the issue Submit the form A confirmation of the receipt of the claim will be sent to you within 2 business days If you have not received a confirmation Email by then please contact techsupport technimount com If...

Page 40: ...Return To Table of Contents 40 BP76 UG 202110 01 www technimount com SAE Certification ...

Page 41: ......

Page 42: ...e it matters most Technimount E M S Holding Inc 3770 Jean Marchand Street Suite 100 C Quebec QC G2C 1Y6 Canada T 1 888 639 2758 F 1 855 339 6351 technimount com info technimount com 2021 Technimount E M S Holding Inc All Rights Reserved Printed in Canada ...

Reviews: