background image

www.technifor.com

Technifor reserves all rights to modify its products. 
This document is non contractual. 

OPERATING AND MAINTENANCE MANUAL 

UC500

CONTROL UNIT FOR MARKING MACHINES 

Ref

. DCD01/3067 -

 UC500_en

_D -

 L

ast

 u

p

d

a

te

d

: 01/200

Summary of Contents for UC500

Page 1: ...r com Technifor reserves all rights to modify its products This document is non contractual OPERATING AND MAINTENANCE MANUAL UC500 CONTROL UNIT FOR MARKING MACHINES Ref DCD01 3067 UC500_en_D Last upda...

Page 2: ...request 10 C Communication 12 1 RS232 cable 12 2 Dedicated Inputs Outputs 12 Wiring of the female 9 SubD connector 12 Connection diagram for the dedicated Inputs Outputs 13 Description of the communi...

Page 3: ...ing Depending on the order the Control Unit is packed on its own or with a machine Work station safety Indicates different safety precautions to be taken during installation and operation of the machi...

Page 4: ...C of the European Parliament and of the Council of 22 June 1998 on the harmonisation of the Member States concerning machines Declaration of compliance to other directives Equipment is compliant with...

Page 5: ...s turned on Grounding must be done according to the regulations in effect to ensure the safety of the personnel Do not use this marking equipment in an explosive environment This Control Unit is exclu...

Page 6: ...ontrol Unit is supplied with 1 bridged male SubD9 connector for the reset function 2 feet 2 truss head screws so it can be installed on a workbench 2 plates 4 countersunk head screws for wall mounting...

Page 7: ...x 180 mm 7 087 in x 150 mm 5 906 in weight pneumatic version 3 9 kg 8 598 lb electromagnetic version 4 1 kg 9 039 lb 3 Technical specifications pneumatic micro percussion and scribing machines power...

Page 8: ...uts 4 On Off fuse carrier 5 Power supply input 90 253 V AC 50 60 Hz 6 Connections to the marking head 7 Ventilator electromagnetic version only 8 Circular marking device option 9 EC plate 10 Two mount...

Page 9: ...25F generic Inputs Outputs 4 On Off fuse carrier 5 Power supply input 90 253 V AC 50 60 Hz 6 Connections to the marking head 7 Ventilator electromagnetic version only 8 Circular marking device option...

Page 10: ...t Head CCU connecting cable Ref MCOLE300 36 6 m 19 685 ft Head CCU connecting cable Ref MCOLE300 37 10 m 32 808 ft Head CCU connecting cable Ref MCOLE300 38 15 m 49 212 ft Head CCU connecting cable Re...

Page 11: ...n button is used to launch marking same function as the foot pedal The red button is used to stop either a single marking in progress or a series of markings before it reaches the end Pneumatic versio...

Page 12: ...nctions Use exclusively shielded cable Connect the shielding to the electrical ground on either side of the cable Number Description Allocation 1 Internal power supply 24 V 300 mA max 2 Relay 2 Output...

Page 13: ...supply available on the connector of the CCU 24 V DC The Marking in progress Machine ready and Fault Outputs are wired to an external power supply SubD 9F Machine Communication CCU side Start marking...

Page 14: ...n Machine ready is available between pins 6 and 7 It is provided by a potential free dry contact relay contact This signal indicates that the CCU has received all the instructions required to perform...

Page 15: ...ected if failure occurs origin or EM machine temperature failures the Fault signal goes to phase 1 The other signals return to phase 0 until operator acknowledgement In process mode Launch a Start cyc...

Page 16: ...ACommunication C Ref DCD01 3067 UC500_en_D 16 27 Maintained mode End of marking cycle Marking Marking Impulse Start cycle Information Marking in progress Ready to marking Marking File loaded...

Page 17: ...ACommunication C Ref DCD01 3067 UC500_en_D 17 27 Pulse mode End of marking cycle Marking Marking Impulse Start cycle Information Marking in progress Ready to marking Marking File loaded...

Page 18: ...ound on either side of the cable Number Description 1 24 V 300 mA max 2 Input I0 3 Input I1 4 Input I2 5 Input I3 6 Negative reference of the I0 I1 I2 I3 Inputs common 7 Gnd 8 Output O0 9 Output O1 10...

Page 19: ...le on pins 1 and 14 and referenced Gnd on pins 7 10 20 23 Note The 24 V internal voltage pins 1 and 14 is not protected from short circuits The current delivered by the 24 V voltage pins 1 and 14 shou...

Page 20: ...Output is 40 mA Remarks The 24 V internal voltage pins 1 and 14 is not protected from short circuits The current delivered by the 24 V voltage pins 1 and 14 should not exceed 300 mA The Outputs are n...

Page 21: ...oot directory of the file tree structure on the USB key Do not place them in directo ries The hard drives are not dealt with Never remove the key during a transfer between the CCU and the key Doing so...

Page 22: ...nly used to test the machine Under normal operating conditions open the electrical connection between pins 5 and 9 to activate the Stop marking function If this connection is not performed the Stop fu...

Page 23: ...the I position On The machine is operational 6 Assembling the accessories Mounting the supporting feet Case of the CCU installed on a workbench Screw the supporting feet to the underside of the CCU a...

Page 24: ...back of a cabinet The back panel of the CCU has 4 mounting holes A screw is already attached in one of these holes Remove this screw Attach the plates to the back panel of the CCU and check that they...

Page 25: ...perform the assembly imperatively use the mounting kit provided Attach the mounting brackets to the rackable panel Remove the feet that may be attached to the CCU Place the CCU on the brackets Attach...

Page 26: ...A 90 253 V AC ELE01 3427 Electromagnetic machines Power Power supply Ref Fuse 5 x 20 6 A UL 198 G and CSA C22 2 norm Time delay 6 A 90 253 V AC SEUC005 16 Description Things to check Action The screen...

Page 27: ...h se POLAND GravoTech Sp zoo Ul Gen Grota Roweckiego 168 PL 52 214 WROCLAW Tel 48 71 796 04 01 Fax 48 71 796 04 02 E mail infopl technifor com CHINA GravoTech Engraving Equipment Co Ltd N 3388 Humin R...