eth oam linkmonitor
Configure the link monitor.
SYNTAX:
eth oam linkmonitor
[state = <{disabled|enabled}>]
[poll-period = <number{1-60}>]
[retransmit-count = <number{0-5}>]
[ef-window = <number{10-65535}>]
[ef-threshold = <number{0-65535}>]
[efp-window = <number{15-65535}>]
[efp-threshold = <number{0-65535}>]
[efss-window = <number{10-65535}>]
[efss-threshold = <number{0-65535}>]
[esp-window = <number{25-65535}>]
[esp-threshold = <number{0-65535}>]
where:
state
Enable/disable Link Monitor.
OPTIONAL
poll-period
Link polling period (in seconds).
OPTIONAL
retransmit-count
Notification events retransmit count.
OPTIONAL
ef-window
Errored Frame Event window (x 100ms) - standardized
range: 100 - 600.
OPTIONAL
ef-threshold
Errored Frame Event threshold.
OPTIONAL
efp-window
Errored Frame Period Event window (x10E+4 frames) -
standardized range: 1 - 900 (100Base-T).
OPTIONAL
efp-threshold
Errored Frame Period Event threshold.
OPTIONAL
efss-window
Errored Frame Seconds Summary Event window (x 100ms)
- standardized range: 100 - 9000.
OPTIONAL
efss-threshold
Errored Frame Seconds Summary Event threshold.
OPTIONAL
esp-window
Errored Symbol Period Event window (x10E+6 symbols) -
standardized range: 25 - 1500 (100Base-T).
OPTIONAL
esp-threshold
Errored Symbol Period Event threshold.
OPTIONAL