24.6
COM51 Software Reset
This section allows you to initiate software reset on the card identified in the “CardIP” field.
➢
Activating this feature is the equivalent to pushing the recessed reset button on the face of
the COM51card and has a similar effect as pressing the small reset button on a traditional
set-top box.
Figure 39 - Reset Interface
24.7
COM51 File Transfer Utility
Similar in function to the upgrade section found on the PairingInfo page, this section provides
you with a method of transferring software updates and license files to or transferring log data
from individual COM51 cards. See Section 11 for more information on upgrading your COM51
cards.
Figure 40 - File Transfer Interface
Following is a brief explanation of each field shown above:
Usage
- This field is used to tell the COM51 which type of transfer to execute. Only four values
are available for customer use (all others are for development purposes only):
1 = MT – This option allows you to upload the special MediaTune authorization and
channel guide files. See COM3000 Technical Support - Mediatune Installation Folder on
the Technicolor / MCS website for details.
2 = Software Upgrade – This option is used to update the COM51 software. In this case,
the file is downloaded to the COM51 card displayed in the browser’s URL field.
3 = Log – This option tells the COM51 to transfer its log file to the destination entered in
the “IP_Address” field (i.e., log file is uploaded to PC).
4=License – This option uploads the XML license file that enables advanced features on
the COM51 such as the HD upgrade for the COM51-A.
Options above 5 & 6 are not enabled for field use.
Server_IP_Address
- This field tells the COM51 card where to retrieve the software update or
license file or where to send the log file, based upon the “Usage” setting above. The default
value for this field is 192.168.1.254.