General operating and safety strategy of Technica 

Engineering’s Products

 

 

Technica Engineering’s products are designed for operation in automotive systems 

and for supply voltages of nominal 12 V or 24 V. The applicable limit values adhere to 
the  standard  norms  for  12  V  or  24  V  automotive  onboard  power  systems 
correspondingly and can be found in the mentioned norms. 
 

Should Technica Engineering’s products be operated in voltage ranges beyond

 those 

specified in the norms, which represents a breach of the conditions of operation, then 
this will void the product warranty and Technica Engineering will assume no liability 
whatsoever of the results and/or consequences thereof.  
 

This is especially valid whenever the voltage level reaches or exceeds the limits of the 
low-voltage directive. In this case, damage to the devices cannot be excluded. Due to 
the manufacturing characteristics of the devices, there is no imminent fire hazard from 
the device itself, if the devices are being operated in an environment according to the 

conditions  of  use.  A  secondary  fire  hazard  cannot  be  excluded,  should  those 
conditions not be met. A protection against overvoltage cannot be provided in such a 
breach of the conditions of use. 
 

1.1.5

 

General design rules for the power supply of Technica 

Engineering’s products

 

 

The power supply circuit of Technica Engineering’s products are equipped with self

-

protection  components.  This  automatic  function  protects  the  devices  against 
excessive temperature and too high supply-voltage by switching the device off. This 

automatic switch-off function is independent of any software function.  
 
The root-cause of excessive temperature in the power supply circuit can eventually be 
due to a too high environment temperature or due to an internal failure of the device. 

In both cases, the automatic switch-off function will switch-off the power supply from 
the device to avoid further damage. 
 
The protection against too high supply-voltage protects the device even in case of an 

internal failure of the Technica Engineering device. 
 

Summary of Contents for TE-1437

Page 1: ...100BASE T1 MEDIACONVERT ER BCM Manual Version 2 4 Hardware Version 2 3 USER MANUAL July 2020 1000BASE T1 SFP MODULE A2 PHY Software Version 1 1...

Page 2: ...echnica Engineering s products 5 1 2 Warranty and Safety Information 6 1 3 RoHS Certificate of Compliance 8 2 HARDWARE INTERFACES 9 2 1 Molex Connector 9 2 2 SFP Socket Connector 10 3 STARTUP AND CONF...

Page 3: ...Pluggable slot It uses the SGMII and generates 1000 Mbit s full duplex Note SERDES interface is not supported Note 100BASE T1 is not supported After power up it self configures to Automotive 1000BASE...

Page 4: ...or A0 compatible mode settable via phy register settings Fits into a standard SFP slot Power requirements 3 3 Volt DC Supports I2C for internal register access Master Slave either via small DIP switc...

Page 5: ...ere is no imminent fire hazard from the device itself if the devices are being operated in an environment according to the conditions of use A secondary fire hazard cannot be excluded should those con...

Page 6: ...test environment includes test setups or test benches in the office laboratory and workshop areas In the test setups the same environmental conditions apply as in vehicle electrical systems Technica E...

Page 7: ...space This symbol is only valid in the European Union If you wish to discard this product please contact your local authorities or dealer and ask for the correct method of disposal Technica Engineeri...

Page 8: ...1000BASE T1 SFP MODULE User Manual 8 1 3 RoHS Certificate of Compliance Figure 1 2 Copy Of RoHS Certificate of compliance...

Page 9: ...uses Molex 0533250260 Header 2 0mm Molex 510900200 Housing Molex 50212 8000 Crimp Contact Name Picture Part Number Molex Header 2 0mm 0533250260 Molex Housing 51090 0200 Molex 50212 8000 Crimp Contac...

Page 10: ...Socket connector Pin Function Pin Function 1 GND 11 GND 2 GND 12 SGMII_RXD_N 3 n c 13 SGMII_RXD_P 4 I2C_DAT 14 GND 5 I2C_CLK 15 3 3 Volt 6 GND 16 3 3 Volt 7 n c 17 GND 8 GND 18 SGMII_TXD_P 9 n c 19 S...

Page 11: ...interface This lasts 100ms Do not apply any I2C activity on the bus during this time 3 2 Self Configuration The SFP Module configures itself to 1000BASE T1 after power up Master Slave Configuration is...

Page 12: ...ress 0x50 Note b1010 000X 0xA0 Read access beyond address 95 will return 0x00 The 88Q2112_A2 transceiver can be accessed at I2C slave 7 bit address 0x40 Note b1000 000X 0x80 The 88Q2112_A1 PHY does no...

Page 13: ...00 37 39 Vendor ID 1 0 0 B A S E T 1 40 55 PartNumber 1 1 0x00 56 59 Revision Number 1 1 0x00 0x00 0x00 60 62 Reserved 0xBC 63 Check Code for Field 0 62 0x00 0x00 64 65 Options 0x00 66 Bitrate max 0x0...

Page 14: ...rent address of the SFP module b1010000X 3 3 3 2 Random address read The random address read requires two operations to perform the read Example Read a random address of the SFP module b1010000X First...

Page 15: ...fied 3 3 3 3 Sequential read The sequential reads are started by either a current word address read or a random address read To specify a sequential read the host responds with an acknowledge instead...

Page 16: ...data word address following the device address write word and acknowledgement Example Byte write operation into the SFP module b1010000X 3 3 3 5 Sequential write The sequential write is started in th...

Page 17: ...r Defines the device number of the register to access Register_address_MSB Defines the Most significant byte of the register to access Register_address_LSB Defines the Less Significant Byte of the reg...

Page 18: ...hen the writing operation is finished This flag can be read after writing the PHY_register_data_LSB to ensure that the data has finished writing PHY_register_data_MSB When a reading operation this reg...

Page 19: ...1000BASE T1 SFP MODULE User Manual 19 4 ADDITIONAL INFORMATION The 1000BASE T1 Port is optimized for automotive UseCase The maximum line length for each 1000BASE T1 segment is limited to 10 meters...

Page 20: ...1000BASE T1 SFP MODULE User Manual 20 5 LIST OF FIGURES Figure 1 1 1000BASE T1 SFP Module A2 Phy 3 Figure 1 2 Copy Of RoHS Certificate of compliance 8 Figure 3 1 DIP Switch 11...

Page 21: ...of A2 Phy 08 05 2019 2 2 All Rework 25 09 2019 2 3 Cover and 1 2 Rework and update Jun 2020 2 4 1 1 4 Added information on General Operating and Safety Strategy of Technica Engineering s Products July...

Page 22: ...his product please feel free to contact us Technica Engineering GmbH Leopoldstr 236 80807 M nchen Germany Technical support support technica engineering de General information Info technica engineerin...

Page 23: ...ineering GmbH et toode h ivamismoodul 1000BASE T1 SFP Module TE 1437 vastab direktiivi 2014 30 EL nuetele ELi vastavusdeklaratsiooni tielik tekst on kttesaadav jrgmisel internetiaadressil https techni...

Page 24: ...echnica engineering de produkt 1000base t1 sfp module Malti B dan Technica Engineering GmbH niddikjara li l prodott 1000BASE T1 SFP Module TE 1437 huwa konformi madDirettiva 2014 30 UE It test kollu t...

Page 25: ...e EU o skladnosti je na voljo na naslednjem spletnem naslovu https technica engineering de produkt 1000base t1 sfp module Slovensky Technica Engineering GmbH t mto vyhlasuje e produkt 1000BASE T1 SFP...

Reviews: