background image

7

Remote Control Unit (Display)

(1) Operation mode

AUTO .....................................

HEAT ......................................

MILD DRY ..............................

COOL .....................................

FAN ........................................

(2) Fan speed

Automatic operation ...............

HIGH .....................................

MEDIUM.................................

LOW .......................................

(3) Temperature setting 

16 – 30 °C
When set to 28 °C 
temperature indication............

(4) Timer

24-hour clock with ON/OFF 
program Timer........................

ON Timer................................

OFF Timer. .............................

1-hour OFF Timer...................

(5) NIGHT SETBACK ..................

(6) Confirmation of transmission..

(7) Auto. flap indication ................

Flap angle indication ..............

Sweep indication ....................

(8) High power operation .............

(9) Quiet operation.......................

(10) LED CLEAN operation.......................

Displayed when setting timer

Displayed when transmitting data

Displayed when indoor unit sensor 
is in use

Displayed when setting 
temperature

Displayed when temperature is 
shown

Displayed when the

time display is set to

12-hour time.

Symbols

Summary of Contents for MPAF120MR5I

Page 1: ...rtida sistema split Climatiseurs split Split klimager t Condizionatore d aria split system Aparelho de ar condicionado Sistema Split Save These Instructions Guard is estas instrucciones Conserver ce n...

Page 2: ...ally sets the flap to the optimum position during heating cooling and drying operation Hot Start Heating System Right from the start the air is warm and comfortable This system prevents any cold blast...

Page 3: ...and serial numbers are on the nameplate on the bottom of the cabinet Model No ______________________ Serial No ____________________ Date of purchase ________________________________________________ D...

Page 4: ...o not install this air conditioner where there are fumes or flammable gases or in an extremely humid space such as a greenhouse Do not install the air conditioner where excessively high heat generatin...

Page 5: ...is blown out of the air conditioner through the air outlet Remote Control Unit The wireless remote control unit controls power ON OFF operation mode selection temperature fan speed timer setting and...

Page 6: ...een mode but no FAN mode at M of the S M switch on the remote control unit The OPERATION lamp lights up red and orange alternately when the system is defrosting TIMER lamp This lamp lights when the sy...

Page 7: ...imer OFF Timer 1 hour OFF Timer 5 NIGHT SETBACK 6 Confirmation of transmission 7 Auto flap indication Flap angle indication Sweep indication 8 High power operation 9 Quiet operation 10 LED CLEAN opera...

Page 8: ...uttons on the remote control unit the mark appears in the display to transmit the setting changes to the receiver in the air conditioner Sensor A temperature sensor inside the remote control unit sens...

Page 9: ...5 Night Setback Mode When you press this button in the HEAT DRY or COOL mode the mark appears in the display and the remote control unit will automatically adjust the set temperature to save energy F...

Page 10: ...control unit should not be bent The remote control unit sends the temperature signal to the air conditioner regularly at five minute intervals If the signal from the remote control unit stops for more...

Page 11: ...from the remote control unit every 5 minutes Mounting the Remote Control Unit Before mounting the remote control unit press the ON OFF operation button at the mounting location to make sure that the...

Page 12: ...ker on the power panel is turned on Once mode is selected and the unit is preset by following the steps below you can have the air conditioner automatically bring the room to the desired temperature s...

Page 13: ...on For fan only operation No FAN mode at M of the S M switch on the remote control unit STEP 2 To start the air conditioner press the ON OFF operation button STEP 3 Press the TEMP setting buttons to c...

Page 14: ...in 5 minute time delay circuit to ensure reliable operation When the operation button is pressed the compressor will start running within three minutes In the event of power failure the unit will sto...

Page 15: ...the indoor temperature when night setback was selected This enables you to save energy without sacrificing comfort This function is convenient when gentle cooling is needed Setting temperature Press...

Page 16: ...dless of the desired temperature The fan speed is 1 step above High HIGH POWER Mode cannot be used when the operation mode is Automatic Operation QUIET Mode and HIGH POWER Mode cannot be used at the s...

Page 17: ...tely until defrosting is completed Heating operation restarts after several minutes This interval will vary slightly depending upon the outdoor temperature and the way in which frost forms Cold draft...

Page 18: ...ance Return button until PM 10 30 is displayed The time can be set in 1 minute increments Holding down the button advances the time rapidly in 10 minute increments 3 Press the CLOCK button again This...

Page 19: ...timer operates as if it is turned off Operation Indication 1 Press the ON TIME setting button once The timer indication is displayed and the present ON time is shown 2 Press the Advance Return button...

Page 20: ...nues to operate for one hour from that point in time and then stops It is not possible to use the OFF Timer and 1 Hour OFF Timer together Whichever function is set last takes precedence If the 1 HR TI...

Page 21: ...osition position until the air being blown out of the unit begins to warm Once the air warms up the flap position and fan speed change to the settings specified with the remote control Use the FLAP bu...

Page 22: ...water on the indoor unit to clean it This will damage the internal components and cause an electric shock hazard Casing and Grille Indoor Unit Clean the casing and grille of the indoor unit with a vac...

Page 23: ...front panel 2 Remove the anti mold filter Cleaning Use a vacuum cleaner to remove light dust If there is sticky dust on the filter wash the filter in lukewarm soapy water rinse it in clean water and d...

Page 24: ...iluted 1 500 for 1 to 2 minutes then wash it Rinse the filter in clean water then let it dry on the towel in room temperature Do not bend nor give excessive force onto the air clean filter If the filt...

Page 25: ...e heat source if possible 3 Doors and or windows are open 3 Shut them to keep the heat or cold out 4 Obstacle near air intake or air discharge port 4 Remove it to ensure good airflow 5 Thermostat is s...

Page 26: ...ou aupr s des revendeurs assurant ce ser vice Eliminer s par ment un quipement lectrique et lectronique et sus piles permet d viter des potentielles retom b es n gatives pour l environnement et la sa...

Page 27: ...R410A est un gaz fluor effet serre couvert par le protocole de Kyoto avec un potentiel de chauffage global GWP 1975 DE Zerstreuen Sie R410A in Atmosph re nicht R410A ist ein fluoriertes Gas abgedeckt...

Page 28: ...fied with out prior notice Per garantire un costante miglioramento dei nostri prodotti ci riserviamo di modificarli senza preavviso Par souci d am lioration constante nos produits peuvent tre modifi s...

Reviews: