Technibel KPA8FIA0R5IBA Operating Instructions Manual Download Page 5

5

EG

REMOTE CONTROL UNIT

DISPLAY

Information is displayed when the remote controller is switched 

on. If switched off, only the operating mode, the room temperature 

and the clock are shown

Operation mode

Fan speed

High speed

Automatic

Medium speed

Low speed

Displayed when 
transmitting data 

Set point 
temperature

I FEEL mode is active 
(remote controller 
sensor active)

Timer modes

Automatic

Cooling
Heating

Dehumidification 
Fan

C

Clock

Room 
temperature

Night
mode

Oscillation
Flap

Filter Ti0

2

 is ON

HIGH POWER
mode

TRANSMITTER

When you press 

the buttons of the 

remote control unit, 

the           mark         

a p p e a r s   o n   t h e 

display to transmit 

the setting changes 

to the receiver in the 

air conditioner.

hOURS  AND  MINUTES  SETTING 

BUTTONS

With these buttons is possible to set the 

clock and the timer. For details refer to 

paragraphs “ SETTING THE HOUR” and 

“SETTING THE TIMER”.

TIMER SELECTION BUTTON

Press this button to select the type of 
timer to activate. For details refer to 
paragraph “SETTING THE TIMER”.

C

TEMPERATURE SETTING BUTTONS

-  (cooler)

Press this button to decrease the set 

temperature.

+ (warmer)

Press this button to increase the set 

temperature.

SENSOR

A   t e m p e r a t u r e 

sensor inside the 

remote control unit 

detects the room 

temperature.

CLOK AND TIMER SETTING BUTTON

Press this button in order to:

• set the clock

• set the ON/OFF timer

For details refer to paragraphs “SETTING 

THE HOUR” and “SETTING THE TIMER”.

IFEEL/IFEEL C SENSOR SELECTOR

Press this button to modify the active 
setting for room temperature detection 
(from remote controller to air conditioner 
and viceversa).

“FAN “ BUTTON (fan speed)

 

Fan speed is automatically 
s e l e c t e d   b y   t h e 
microcomputer. 

 

High speed.

 

Medium speed.

 

Low speed.

ON/OFF BUTTON

This button turns the air conditioner ON 

and OFF.

FLAP BUTTON

Press this button in order to select the 

desired function.

Fixed: six position

Continous oscillations

Automatically oscillations

NIGhT/ECO BUTTON

Press this button in order to select the 

NIGHT/ECO mode.

“hIGh POwER” BUTTON

Press this button in order to select the 

HIGH POWER mode.

MODE SELECTOR BUTTON

Press this button to modify the air 

conditioner mode.
 

(cooling)

 

The air conditioner makes the room 

cooler.
 

(dry) 

The air conditioner reduces the humidity 

in the room.

 

(automatic)

When this setting is selected (+ IFEEL 

ON), the unit calculates the difference 

between the thermostat setting and 

the perceived room temperature and 

automatically switches to the “cool” or 

“heat” mode.
 

(fan)

The air conditioner works only as a 

circulation fan.

Inverter model

MENU BUTTON

Use this button in order to enter the 
functions menu.

MODE SELECTOR BUTTON

Press this button to modify the air 
conditioner mode.

 

(heating)

The air conditioner makes the room 
warmer.

Fixed symbol

: the fan stops when the set 

temperature is exceeded.

B l i n k i n g   s y m b o l   ( h E A T I N G 

RECIRCULATION  FUNCTION)

: the 

fan keeps running even after the set 

temperature is exceeded.

  

(automatic)

When this setting is selected (+ IFEEL ON), 

the unit calculates the difference between 

the thermostat setting and the perceived 

room temperature and automatically 

switches to the “cool” or “heat” mode.

Summary of Contents for KPA8FIA0R5IBA

Page 1: ...em Condizionatore d aria split system Climatiseurs split Split klimager t Acondicionador de aire de consola partida sistema split KPA8FIA0R5IBA KPA9FIB0R5IBA NOTICE D UTILISATION OPERATING INSTRUCTION...

Page 2: ...NERGY SAVING 11 TROUBLESHOOTING 11 EXPLANATION AND USE OF THE REMOTE CONTROL UNIT S MICROSWITCHES 15 NOTE PRODUCT INFORMATION If you have problems or questions concerning your Air Conditioner you will...

Page 3: ...ect the power Use the main power switch to turn off power completely WARNING EG NAME OF PARTS AND OPERATION SELECTOR switch 7 8 9 5 3 4 2 1 6 OFF LAMPS FUNTION It is possible to set the air conditione...

Page 4: ...he remote control unit and check the settings of the four microswitches as shown below TEMPERATURE SENSOR SELECTOR l Under normal conditions the room temperature is detected and checked by the tempera...

Page 5: ...n to modify the active setting for room temperature detection from remote controller to air conditioner and viceversa FAN BUTTON fan speed Fan speed is automatically s e l e c t e d b y t h e microcom...

Page 6: ...to the setting you want During Automatic Operation IFEEL ON the set temperature is understood as perceived one then the system is automatically adjusted not only according to the air temperature but a...

Page 7: ...es the operation mode cooling or heating for all the other units that will be switched on after the first one when the system has been switched on in cooling mode and one unit is activated in heating...

Page 8: ...utton to turn the air conditioner off l Wait for the indoor unit to stop operating l Press the ON OFF button again to turn the air conditioner on SETTING THE 1 HOUR TIMER This function causes the unit...

Page 9: ...air warms up the flap position and fan speed change to the settings specified with the remote control Use the FLAP button on the remote control to adjust the position of the flap If you move the flap...

Page 10: ...low the steps below 1 When the air conditioner is stopped If you want to turn on the air conditioner push the OPERATION selector with a pen to select the desired mode COOL or HEAT OPERATION WITHOUT TH...

Page 11: ...t 4 Remove it to ensure good airflow 5 Set the right temperature on the remote control unit 6 Try to use a back up heater 7 Consult your dealer Trouble Clicking sound is heard from the air conditioner...

Page 12: ...p is closed The system restarts automatically as soon as a correct operating mode is selected Set the outdoor indoor unit refrigerant circuit address see Installation Instructions Select an available...

Page 13: ...ck that the dip switch SW2 for communication address setting is in the correct position Check that all earth cables are properly connected to every terminal C h e c k t h a t t h e s h i e l d o f t h...

Page 14: ...cal wiring diagram Check that the sensor is not damaged and if necessary replace it E6 O F F Fan motor error Fan is stopped and flap is closed The system restarts automatically after some seconds Chec...

Page 15: ...ler providing this service Disposing of a battery separately avoids possible negative effects on the environment and human health deriving from an inappropriate disposal and enables its components to...

Page 16: ...Z I Route d partementale 28 01600 Reyrieux France T l 33 4 74 00 92 92 Fax 33 4 74 00 42 00 Technibel is a trademark of NIBE ENERGY SYSTEM FRANCE...