1.  Remote control unit.

2.  Remote control sensor:

 Detects the room temperature 

around the remote control unit, the air conditioner is 
controlled accordingly.

3.  Air outlet:

 Conditioned air is blown out of the air 

conditioner through the air outlet.

4. 

Air intake:

 Air from the room is drawn into this section 

and passes through air filter which removes dust.

5.  Remote control receiver:

 This section picks up infrared 

signals from the remote control unit (Transmitter).

6.  Operation selector (without remote control): 

Push 

the button to walk through the operation modes (OFF, 
COOL and HEAT)

 

   

7.  OPERATION lamp:

 This lamp lights up during 

operation.
It blinks once to announce that the remote control 
signal has been received and stored.

8.  STANDBY lamp:

 This lamp lights up when the air 

conditioner is connected to the power and ready to 
receive the remote control command.

9.  TIMER lamp: 

This lamp lights up when the system is 

being controlled by the timer.

The OFF position does not disconnect the power. Use 

the main power switch to turn off power completely.

WARNING

EG

NAME OF PARTS AND OPERATION SELECTOR SwITCh

7 8 9

5

3

4

2

1

6

OFF LAMPS FUNTION

It is possible to set the air conditioner in order to let the 
OPERATION, TIMER and STANDBY lamps always OFF, 
even during operation.
Be sure that the remote controller is ON (using the ON/
OFF button) and that the symbol           on the display of 
remote controller is OFF, then Press contemporary the 
IFEEL and FAN buttons on the remote control unit for more 
then 5 seconds.
Repeat the same procedure to set again the normal 
operation conditions.

If the air conditioner is powered, but the lamps are off, try 
to activate them using this procedure.

In case of troubleshooting the air conditioner diagnostic 
system activates the lamps accordingly, even if they are 
set to OFF. See paragraph TROUBLESHOOTING for 
further details.

The  blinking  of  TIMER  and  STANDBY  lamps  and 

OPERATION lamp ON, indicates that: 

1. 

Indoor unit has not been addressed. 

2. 

heating mode has been selected, when the system 

was in cooling mode, or vice versa.  

 

Select the correct mode, compatible with the 

system.

SEE AUTO-DIAGNOSIS TABLE

MULTI SPLIT SYSTEM

only

Summary of Contents for KPA8FIA0R5IBA

Page 1: ...em Condizionatore d aria split system Climatiseurs split Split klimager t Acondicionador de aire de consola partida sistema split KPA8FIA0R5IBA KPA9FIB0R5IBA NOTICE D UTILISATION OPERATING INSTRUCTION...

Page 2: ...NERGY SAVING 11 TROUBLESHOOTING 11 EXPLANATION AND USE OF THE REMOTE CONTROL UNIT S MICROSWITCHES 15 NOTE PRODUCT INFORMATION If you have problems or questions concerning your Air Conditioner you will...

Page 3: ...ect the power Use the main power switch to turn off power completely WARNING EG NAME OF PARTS AND OPERATION SELECTOR switch 7 8 9 5 3 4 2 1 6 OFF LAMPS FUNTION It is possible to set the air conditione...

Page 4: ...he remote control unit and check the settings of the four microswitches as shown below TEMPERATURE SENSOR SELECTOR l Under normal conditions the room temperature is detected and checked by the tempera...

Page 5: ...n to modify the active setting for room temperature detection from remote controller to air conditioner and viceversa FAN BUTTON fan speed Fan speed is automatically s e l e c t e d b y t h e microcom...

Page 6: ...to the setting you want During Automatic Operation IFEEL ON the set temperature is understood as perceived one then the system is automatically adjusted not only according to the air temperature but a...

Page 7: ...es the operation mode cooling or heating for all the other units that will be switched on after the first one when the system has been switched on in cooling mode and one unit is activated in heating...

Page 8: ...utton to turn the air conditioner off l Wait for the indoor unit to stop operating l Press the ON OFF button again to turn the air conditioner on SETTING THE 1 HOUR TIMER This function causes the unit...

Page 9: ...air warms up the flap position and fan speed change to the settings specified with the remote control Use the FLAP button on the remote control to adjust the position of the flap If you move the flap...

Page 10: ...low the steps below 1 When the air conditioner is stopped If you want to turn on the air conditioner push the OPERATION selector with a pen to select the desired mode COOL or HEAT OPERATION WITHOUT TH...

Page 11: ...t 4 Remove it to ensure good airflow 5 Set the right temperature on the remote control unit 6 Try to use a back up heater 7 Consult your dealer Trouble Clicking sound is heard from the air conditioner...

Page 12: ...p is closed The system restarts automatically as soon as a correct operating mode is selected Set the outdoor indoor unit refrigerant circuit address see Installation Instructions Select an available...

Page 13: ...ck that the dip switch SW2 for communication address setting is in the correct position Check that all earth cables are properly connected to every terminal C h e c k t h a t t h e s h i e l d o f t h...

Page 14: ...cal wiring diagram Check that the sensor is not damaged and if necessary replace it E6 O F F Fan motor error Fan is stopped and flap is closed The system restarts automatically after some seconds Chec...