Technibel KPA8FIA0R5IBA Operating Instructions Manual Download Page 11

11

EG

TIPS FOR ENERGY SAVING

DO NOT:

l

 

Block the air intake and outlet of the unit. 

  If they are obstructed, the unit will not work well, and 

may be damaged.

l

 

Let direct sunlight into the room. Use sunshades,  

blind or curtain.

DO:

l

 

Always try to keep the air filter clean. A clogged filter  

will impair the performance of the unit.

l

 

To prevent conditioned air from escaping, keep 

windows, doors and any other openings closed.

TROUBLEShOOTING

WARNING

l

 

The use of portable telephones near the air conditioner 
may cause disturbance to its normal operation and must  
be avoided. In case abnormal operation is noticed, 
(OPERATION lamp lights, but the air conditioner will not 
run) to restore normal operation turn-off electric supply 
for about 3 minutes, by disconnecting the main switch 
or the wall plug, then start again the air conditioner.

If your air conditioner does not work properly, first check 

the following points before requesting service.

If it still does not work properly, contact your dealer or 

service centre.

Trouble:

 the air conditioner does not run at all.

Possible cause:

1.  Power failure.

2.  Leakage breaker tripped.

3.  Operation button is OFF.

4.  Batteries in remote control unit have run down.

Remedy:

1.  Restore power.

2.  Contact service centre.

3.  Press the button again.

4.  Replace batteries.

Trouble:

 Poor cooling or heating performance.

Possible cause:

1.  Dirty or clogged air filters.

2.  Heat source or many people in room.

3.  Doors and/or windows are open.

4.  Obstacle near air intake or air discharge port.

5.  The set temperature on the remote control unit is too 

high.

6.  Outdoor temperature is too low (heat pump version).

7.  Defrosting system does not work (heat pump version).

Remedy:

1.  Clean air filters to improve airflow.

2.  Eliminate heat source if possible.

3.  Shut them to keep the heat or cold out.

4.  Remove it to ensure good airflow.

5.  Set the right temperature on the remote control unit.

6.  Try to use a back-up heater.

7.  Consult your dealer.

Trouble:

 Clicking sound is heard from the air conditioner.

Possible cause:

1.  During operation, any plastic parts may expand or 

shrink due to a sudden temperature change. In this 

event, a clicking sound may occur.

Remedy:

1.  This is normal, and the sound will disappear when an 

even temperature is settled.

A C T I V A T E D   C A R B O N   A I R   F I L T E R 
(ACCESSORY SUPPLIED ON REQUEST)

NOTE

1.  The activated carbon air filters are in a polyethylene 

bag.

2.  Open the bag just before installing the activated carbon 

air filters, otherwise, the  deodorizing effect durability of 

the filter may be decreased.

The activated carbon air filter is to be added to the 

standard filter.
It is made of two layers:

-  the first layer consists in a synthetic honey comb high 

efficiency media to remove the dust and purifing the 

air.

- the second layer in charcoal media deodorizing the 

ambient air.

REPLACEMENT OF ACTIVATED CARBON 
AIR FILTER

l

 

The filter is disposable.

l

 

Do not throw away the filter frame, if present.

l

 

The used filter cannot be reused even after cleaning up.

l

 

Obtain the filters for replacement at your nearest dealer.

l

 

Check the state of dirtiness at least once every two 
weeks.

l

 

Replace the filter after six months’ operation.

This activated carbon air filter cannot remove harmful 

gases or vapors nor ventilate air in the room. You must 

open doors or windows frequently  when you use gas or oil 

heating appliances. Otherwise there is a risk  of suffocation 

in an extreme case.

WARNING

ACTIVATED  CARBON  AIR  FILTER  INSTALLATION 
PROCEDURE

1.

  Open the unit intake air grille and pull out the standard 

air filter.

2.

  Apply on the rear side of the filter the two spings 

supplied with the accessory.

3.

  Fix the activated carbon filter by the springs.

4.

  Insert the two air filters one over the other and close 

the intake grille.

REAR SIDE OF

AIR FILTER

SPRING

ACTIVATED CARBON 

FILTER

Summary of Contents for KPA8FIA0R5IBA

Page 1: ...em Condizionatore d aria split system Climatiseurs split Split klimager t Acondicionador de aire de consola partida sistema split KPA8FIA0R5IBA KPA9FIB0R5IBA NOTICE D UTILISATION OPERATING INSTRUCTION...

Page 2: ...NERGY SAVING 11 TROUBLESHOOTING 11 EXPLANATION AND USE OF THE REMOTE CONTROL UNIT S MICROSWITCHES 15 NOTE PRODUCT INFORMATION If you have problems or questions concerning your Air Conditioner you will...

Page 3: ...ect the power Use the main power switch to turn off power completely WARNING EG NAME OF PARTS AND OPERATION SELECTOR switch 7 8 9 5 3 4 2 1 6 OFF LAMPS FUNTION It is possible to set the air conditione...

Page 4: ...he remote control unit and check the settings of the four microswitches as shown below TEMPERATURE SENSOR SELECTOR l Under normal conditions the room temperature is detected and checked by the tempera...

Page 5: ...n to modify the active setting for room temperature detection from remote controller to air conditioner and viceversa FAN BUTTON fan speed Fan speed is automatically s e l e c t e d b y t h e microcom...

Page 6: ...to the setting you want During Automatic Operation IFEEL ON the set temperature is understood as perceived one then the system is automatically adjusted not only according to the air temperature but a...

Page 7: ...es the operation mode cooling or heating for all the other units that will be switched on after the first one when the system has been switched on in cooling mode and one unit is activated in heating...

Page 8: ...utton to turn the air conditioner off l Wait for the indoor unit to stop operating l Press the ON OFF button again to turn the air conditioner on SETTING THE 1 HOUR TIMER This function causes the unit...

Page 9: ...air warms up the flap position and fan speed change to the settings specified with the remote control Use the FLAP button on the remote control to adjust the position of the flap If you move the flap...

Page 10: ...low the steps below 1 When the air conditioner is stopped If you want to turn on the air conditioner push the OPERATION selector with a pen to select the desired mode COOL or HEAT OPERATION WITHOUT TH...

Page 11: ...t 4 Remove it to ensure good airflow 5 Set the right temperature on the remote control unit 6 Try to use a back up heater 7 Consult your dealer Trouble Clicking sound is heard from the air conditioner...

Page 12: ...p is closed The system restarts automatically as soon as a correct operating mode is selected Set the outdoor indoor unit refrigerant circuit address see Installation Instructions Select an available...

Page 13: ...ck that the dip switch SW2 for communication address setting is in the correct position Check that all earth cables are properly connected to every terminal C h e c k t h a t t h e s h i e l d o f t h...

Page 14: ...cal wiring diagram Check that the sensor is not damaged and if necessary replace it E6 O F F Fan motor error Fan is stopped and flap is closed The system restarts automatically after some seconds Chec...

Page 15: ...ler providing this service Disposing of a battery separately avoids possible negative effects on the environment and human health deriving from an inappropriate disposal and enables its components to...

Page 16: ...Z I Route d partementale 28 01600 Reyrieux France T l 33 4 74 00 92 92 Fax 33 4 74 00 42 00 Technibel is a trademark of NIBE ENERGY SYSTEM FRANCE...

Reviews: