2-2. Major Component Specifications
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
4
Type
Rotary (Hermetic)
Compressor model…Q'ty / Code number C - R N 1 1 0 H 5 B … 2 / 802356-45B
Nominal output
W
1,100
Compressor oil ... Amount cc FV68S ... 550
Coil resistance (Ambient temp. 25°C)
Ω
C – R : 1.962
C – S : 5.38
Type External (OLR A) External (OLR T)
Safety Overload relay … Q'ty MRA98596-9201 CS – 7C115
devices
Operating
Open
°C
145 ± 5
115 ± 3
temp.
Close
°C
69 ± 11
95 ± 5
Operating amp.(Ambient temp. 25°C)
Trip in 6 to 16 sec. at 21 A
—
Run capacitor
µF
25.0 ... 2
... Q'ty VAC 450 ... 2
Type
Propeller
Q'ty ... Dia.
mm
1 ... ø460
Fan motor model ... Q'ty 19TFB6064 ... 1
No. of poles ... rpm (230 V) 6 ... 850-370
Nominal output
W
50
Coil resistance (Ambient temp. 20°C) WHT – BRN : 99.5
WHT – YEL : 25.2
YEL – PNK : 63.2
Safety Type
Internal
protector
devices
Operating Open °C 130
± 5
temp.
Close
Automatic reclosing
Run capacitor
µF
5.0
VAC 400
Coil
Aluminum plate fin / Copper tube
Rows
2
Fin pitch
mm
1.8
Face area
m
2
0.574
External Finish
Acrylic baked-on enamel finish
Heat
Exch. Coil
Compressor
Fan & Fan Motor
Outdoor Unit GRV247M2C5VAA