TECHNICAL DATA
& SERVICE MANUAL

OUTDOOR UNIT:

GR9FI65R5IAA
.

TRIAL SPLIT SYSTEM AIR CONDITIONER 

.

Model No.

Product Code No.

GR9FI65R5IAA

38.7107.102

0.8180.611.01     06/2011

Summary of Contents for GR9FI65R5IAA

Page 1: ...TECHNICAL DATA SERVICE MANUAL OUTDOOR UNIT GR9FI65R5IAA TRIAL SPLIT SYSTEM AIR CONDITIONER Model No Product Code No GR9FI65R5IAA 38 7107 102 0 8180 611 01 06 2011...

Page 2: ...t allow wiring to touch the refrigerant tubing compressor or any moving parts of the fan Do not use multi core cable when wiring the power supply and control lines Use separate cables for each type of...

Page 3: ...ant Flow Diagram 9 4 2 Dual Split System Refrigerant Flow Diagram 10 4 3 Mono Split System Refrigerant Flow Diagram 11 5 PERFORMANCE DATA 12 5 1 Performance Charts 12 6 ELECTRICAL DATA 13 6 1 Electric...

Page 4: ...Outdoor Air Intake Temp Cooling Maximum 32 C D B 23 C W B 43 C D B Minimum 10 C D B 6 C W B 15 C D B 24 C D B 18 C W B Minimum 5 C D B 15 C D B GR9FI65R5IAA Heating Maximum 27 C D B Temperature Indoor...

Page 5: ...mensions Weight Unit dimensions Height mm Width mm Depth mm Package dimensions Height mm Width mm Depth mm Weight Net kg Shipping kg Shipping volume m3 DATA SUBJECT TO CHANGE WITHOUT NOTICE Remarks Ra...

Page 6: ...model Q ty No Of poles rpm Nominal output W Coil resistance Ambient temp 25 C Safety devices Type Operating temp Open C Close C Heat Exch Coil Coil Rows Fin pitch mm Face area m2 External Finish DATA...

Page 7: ...sistance k Thermistor narrow tube B sensor Resistance k Thermistor wide tube C sensor Resistance k Thermistor narrow tube C sensor Resistance k Crank case heater Resistance at 20 C Base heater Resista...

Page 8: ...3 DIMENSIONAL DATA GR9FI65R5IAA dimension mm SERVICE VALVE TUBE 2x 6 35 1 4 NARROW TUBE 3x 6 35 1 4 4 12 for anchor bolt WIDE TUBE 2x 9 52 3 8 1x 12 7 1 2 8...

Page 9: ...xpansion valve is used in the outdoor unit both the wide and narrow tubes of this air conditioner become cold To prevent heat loss and wet floors due to dripping of condensation both tubes must be wel...

Page 10: ...ed in the outdoor unit both the wide and narrow tubes of this air conditioner become cold To prevent heat loss and wet floors due to dripping of condensation both tubes must be well insulated with a p...

Page 11: ...utdoor unit both the wide and narrow tubes of this air conditioner become cold To prevent heat loss and wet floors due to dripping of condensation both tubes must be well insulated with a proper insul...

Page 12: ...0 1 20 10 15 20 25 30 35 40 Outdoor inlet air D B temperature C Low pressure at wide tube service valve MPa 1 5 1 7 1 9 2 1 2 3 2 5 2 7 2 9 0 5 10 15 20 Outdoor inlet air D B temperature C High pressu...

Page 13: ...W B HEATING 3 Indoor Unit Performance at Rating conditions Running Amps A 0 66 7 5 Power input kW 0 148 1 690 Rating Conditions Indoor Air Temperature 20 C D B Outdoor Air Temperature 7 C D B 6 C W B...

Page 14: ...6 2 Electric Wiring Diagram GR9FI65R5IAA 14...

Page 15: ...unit GR9FI65R5IAA Indoor unit MPA9FIB0R5I x1 MTAFIA0R5I x2 6 4 Dual Split System Wiring Diagram Outdoor unit GR9FI65R5IAA Indoor unit MPA9FIB0R5I MTAFIA0R5I 6 5 Mono Split System Wiring Diagram Outdoo...

Page 16: ...r F F F F F automatically restart after 3 min 1 fault on outdoor unit O O F O O during this time the signalling is showed 0 wrong mode selected F F O system does not operate to restart the system sele...

Page 17: ...R D 28 Reyrieux BP 131 01601 Tr voux CEDEX France T l 04 74 00 92 92 Fax 04 74 00 42 00 R C S Bourg en Bresse B 759 200 728...