background image

DSAF94MR5IAA
DSAF124MR5IAA
DSAF184MR5IAA

37.4163.2

54

.0     0

1

/200

5

OPERATING INSTRUCTIONS • NOTICE D’UTILISATION

BEDIENUNGSANLEITUNG • ISTRUZIONI D’USO

INSTRUCCIONES DE USO

Split air conditioner system • Climatiseurs split 

Split- Klimagerät  • Condizionatori d’aria Split System

Acondicionador de aire de consola partida sistema split

DSAF224MR5IAA

Summary of Contents for DSAF124MR5IAA

Page 1: ...RATING INSTRUCTIONS NOTICE D UTILISATION BEDIENUNGSANLEITUNG ISTRUZIONI D USO INSTRUCCIONES DE USO Split air conditioner system Climatiseurs split Split Klimagerät Condizionatori d aria Split System Acondicionador de aire de consola partida sistema split DSAF224MR5IAA ...

Page 2: ...tting of the room temperature thermostat allowing you to set the temperature at whatever level that you find comfortable Automatic and 3 step Fan Speed Auto High Medium Low Air Sweep Control This function moves a flap up and down in the air outlet directing air in a sweeping motion around the room and providing comfort in every corner High Power Cooling When a cooling or drying operation is to be ...

Page 3: ...nameplate on the bottom of the cabinet Model No ______________________ Serial No _________________________ Date of purchase ____________________________________________________ Dealer s address ____________________________________________________ Phone number_____________________ DECLARATION OF CONFORMITY This product is marked as it satisfies EEC Directive No 89 336 EEC 73 23 EEC and 93 68 EEC Th...

Page 4: ...through the supply wiring 3 Wiring must be done by a qualified electrician Safety Instructions Read this Instruction Manual carefully before using this air conditioner If you still have any difficulties or problems consult your dealer for help This air conditioner is designed to give you comfortable room conditions Use this only for its intended purpose as described in this Instruction Manual Neve...

Page 5: ... the remote control unit Set the selector normally in this position OFF Position Switch the selector to the off position if you are not going to use the air conditioner for a few days or longer TEST Position This position is used only for servicing the air conditioner so don t leave the selector in this position for normal operation 11 Operation lamp This lamp lights when the air conditioner is ru...

Page 6: ...SOR DRY COOL 2 Confirmation of transmission 3 Set temperature 16 30 C When set to 28 C Current temperature indication 4 Timer ON Timer OFF Timer 1 hour OFF Timer Remote Control Unit Display Displayed when indoor unit sensor is in use Displayed when setting timer Displayed when transmitting data Displayed when setting temperature Symbols Displayed when setting temperature in automatic operation 6 ...

Page 7: ...peration button This button is for turning the air conditioner on and off When you press this button regardless of whether the unit is operating or stopping the unit operates for one hour and then shuts down Press the button to increase the set temperature Press the button to reduce the set temperature For details see Automatic operation and Manual operation Remote Control Unit Temperature setting...

Page 8: ... air conditioner reduces the humidity in the room COOL The air conditioner makes the room cooler FLAP button Press this button either to select the setting of the airflow direction to the auto flap in each mode or one of the six possible positions manually or to select the sweep function which moves the flap up and down automatically Auto flap setting If selected in a heating operation the flap is...

Page 9: ...g tone beep is heard from the indoor unit Normally the tabs on the remote control unit should not be bent A C SENSOR button When you press this button use a small tipped object such as a ballpoint pen the mark will appear at the display And the room temperature is detected by the sensor which is built into the indoor unit and the air conditioner is controlled accordingly NOTE If the remote control...

Page 10: ... unit Replace the batteries when the remote control unit s display fails to indicate or when the remote control cannot be used to change the air conditioner s settings Use two fresh leak proof type AAA alkaline batteries In replacing batteries follow the instructions as mentioned in the sub section How to Install Batteries If you do not use the remote control unit more than 1 month take out the ba...

Page 11: ...peed and airflow direction Each time one of the temperature setting buttons TEMP is pressed the temperature is changed by 1 C The temperature can be changed from 4 C higher to 4 C lower from the standard temperature setting The upper limit during cooling is 30 C Operation with the Remote Control Unit 1 Automatic Operation Standard temperature settings during automatic operation Type of operation S...

Page 12: ... fan speed can be changed to suit your individual preference It will take a few seconds for the fan speed to be switched 2 Manual Operation NOTE Check that the circuit breaker on the power panel is turned on and that the operation selector of the indoor unit is in the ON position STEP 1 STEP 5 STEP 2 STEP 3 STEP 4 Indoor temperature Outside air temperature Cooling operation Drying operation Temper...

Page 13: ...ike this select a temperature setting which is lower than the current room temperature and perform the drying operation NOTE This appliance has a built in 3 minute time delay circuit to ensure reliable operation When the operation button is pressed the compressor will start running within three minutes In the event of power failure the unit will stop STEP 1 Press the MODE selector button and selec...

Page 14: ...ally during operation just set the FAN SPEED selector button as desired or 4 ECONOMY Mode The ECONOMY Mode is used for saving energy Press the ECONOMY button while the air conditioner is operating The mark appears in the display To cancel the ECONOMY function press the ECONOMY button again Operation with the Remote Control Unit continued 14 ...

Page 15: ...etting 3 C when 60 minutes have passed after the selection was made and then another 4 C after another 2 hours have passed regardless of the indoor temperature when ECONOMY was selected This enables you to save energy without sacrificing comfort This function is convenient when gentle heating is needed NOTE The temperature does not shift in the Auto mode during ECONOMY mode B In Heating Mode Opera...

Page 16: ...t the unit again Clicking Sound Clicking sound is heard from the air conditioner In heating or cooling operation any plastic parts may expand or shrink due to a sudden temperature change In this event a clicking sound may occur This is normal and the sound will soon disappear Remote Control Unit The remote control unit sends the setting condition to the air conditioner regularly at five minute int...

Page 17: ...the time rapidly in 10 minute increments This completes the setting of the current time 2 How to set the OFF time Example To stop the air conditioner at 11 00 am 1 Press the OFFTIME setting button once 2 Press the Advance Return button until AM 11 00 is displayed 3 Press the SET button The timer indication blinks and present OFF time is shown The time can be set in 10 minute increments Holding dow...

Page 18: ...hen the ON timer is used the temperature setting may not be reached by the set time depending on the size and conditions in the room To cancel a timer program Press the CANCEL button When either an ON or OFF timer is to be canceled press the button corresponding to the timer whose program is to be canceled and then press the CANCEL button Operation 1 Press the ONTIME setting button once 2 Press th...

Page 19: ...nd 3 1 2 3 Indication The present time 10 30 pm and are displayed OFF time Present time ON time Daily ON OFF NOTE The ON OFF combination timer uses the current time as the reference and it is activated starting from whichever set time comes first With the ON OFF combination timer the settings are repeated every day You can check the timer ON OFF times after you have set them by pressing the ONTIME...

Page 20: ...er Whichever function is set last takes precedence If the 1 HR TIMER button is pressed while theTIMER OFF function operates the OFF Timer is cancelled and the unit will stop operating one hour later 2 Operation together with the DAILY ON OFF REPEAT Timer Setting the HIGH POWER Operation 1 HIGH POWER Operation This function causes the unit to operate at HIGH POWER in the present mode of operation f...

Page 21: ...ly for 15 minutes the temperature setting has been reached during a cooling or heating operation or the humidity setting has been reached during a drying operation which is only when one indoor unit is operated operation will continue for the next 5 minutes at a reduced power level after which the regular operation is restored If the setting is not reached in either case regular operation is resto...

Page 22: ...control unit or it has trouble follow the steps below 1 When the air conditioner is not running If you want to turn on the air conditioner switch the operation selector to the OFF position and then to the ON position NOTE The set temperature and fan speed are automatically set at the last selection before stopping 2 When the air conditioner is running If you want to turn off the air conditioner sw...

Page 23: ...ve it to ensure good airflow 5 Set the temperature lower or higher 6 Consult your dealer or try to use a back up heater This is normal and the sound will soon disappear 1 Turn off the power then restart the air conditioner after 1 minute 2 Consult your dealer 1 Power failure 2 Leakage circuit breaker tripped 3 Line voltage is too low 4 Operation button is OFF 5 Batteries in remote control unit hav...

Reviews: