2-2 Major Component Specifications

Outdoor Unit:

GRV72C5TA-

Compressor

Type
Compressor model
Nominal output

W

Compressor oil…Amount

cc

Coil resistance (Ambient temp. 25°C)

Overload relay
Safety devices

Type
Operating Temp. Open

°C

Close

°C

Operating amp. (Ambient temp. 25°C)

Run capacitor

µF

VAC

Fan & Fan Motor

Type
Q'ty ……. Dia.
Fan motor model…Q'ty
No. Of poles…rpm (230 V, High)
Nominal output

W

Coil resistance (Ambient temp. 25 °C )

Safety devices

Type
Operating temp. Off

°C

On

°C

Run capacitor

µF

VAC

Heat Exch. Coil

Coil
Rows
Fin pitch

mm

Face area

m

2

External Finish

DATA SUBJECT TO CHANGE WITHOUT NOTICE

WHT-YEL: 408,1

1…. Ø 370

115 ± 3

FV68S…350

C-R: 4,66

145 ± 5
69 ± 11

CS-7C115

6…832

25,05

BRN-WHT: 242,4

802 060 35B   C-1RN60H5C

600

95 ± 5

17,5

450

//

Acrylic baked-on enamel finish

Thermal protector

130 ± 5

1

1,3

0,353

1,5

Aluminium plate fin  / Copper tube

450

Rotary (Hermetic)

83 ± 15

C-S: 8,89

Propeller

UE6-21ST5P…1

External (OLR T)

External (OLR A)

MRA 38072-3229

Trip in 6 to 16 s at 13 A

8

Summary of Contents for 387107047

Page 1: ...ICAL DATA SERVICE MANUAL OUTDOOR UNIT GRV72C5TA GRV92C5TA GRV122C5TA SPLIT SYSTEM AIR CONDITIONER 0 8180 273 0 05 2002 Model No Product Code No GRV72C5TA 387107047 GRV92C5TA 387107048 GRV122C5TA 38710...

Page 2: ...ing to touch the refrigerant tubing compressor or any moving parts of the fan Do not use multi core cable when wiring the power supply and control lines Use separate cables for each type of line When...

Page 3: ...ponent specifications 8 3 DIMENSIONAL DATA 11 4 REFRIGERANT FLOW DIAGRAM 12 5 PERFORMANCE DATA 13 5 1 Performance Charts 13 5 2 Cooling Capacity 16 6 ELECTRICAL DATA 19 6 1 Electrical characteristics...

Page 4: ...1 OPERATING RANGE Temperature Indoor Air Intake Temp Outdoor Air Intake Temp Cooling Maximum Minimum 43 C D B 19 C D B 32 C D B 23 C W B 19 C D B 14 C W B 4...

Page 5: ...able tubing length at shipment m Refrigerant Narrow tube mm in tube diameter Wide tube mm in Dimensions Weight Unit dimensions Height mm Width mm Depth mm Package dimensions Height mm Width mm Depth m...

Page 6: ...shipment m Refrigerant Narrow tube mm in tube diameter Wide tube mm in Dimensions Weight Unit dimensions Height mm Width mm Depth mm Package dimensions Height mm Width mm Depth mm Weight Net kg Shipp...

Page 7: ...shipment m Refrigerant Narrow tube mm in tube diameter Wide tube mm in Dimensions Weight Unit dimensions Height mm Width mm Depth mm Package dimensions Height mm Width mm Depth mm Weight Net kg Shipp...

Page 8: ...W Coil resistance Ambient temp 25 C Safety devices Type Operating temp Off C On C Run capacitor F VAC Heat Exch Coil Coil Rows Fin pitch mm Face area m2 External Finish DATA SUBJECT TO CHANGE WITHOUT...

Page 9: ...ance Ambient temp 25 C Safety devices Type Operating temp Off C On C Run capacitor F VAC Heat Exch Coil Coil Rows Fin pitch mm Face area m2 External Finish 22 5 800 FV68S 470 C R 3 07 C S 7 97 Externa...

Page 10: ...e Ambient temp 25 C Safety devices Type Operating temp Open C Close C Run capacitor F VAC Heat Exch Coil Coil Rows Fin pitch mm Face area m2 External Finish Acrylic baked on enamel finish Aluminium pl...

Page 11: ...IONAL DATA 700 540 15 470 4 12 holes 116 320 294 Air intake Air discharge 255 10 170 103 57 Narrow tube service valve 6 35 1 4 Wide tube service valve 9 52 3 8 12 7 1 2 7000 9000 BTU h 12000 BTU h Uni...

Page 12: ...pillary tube Indoor Unit Outdoor Unit Evaporator Muffler O D 12 7 mm 1 2 Insulation of Refrigerant Tubing Because capillary tubing is used in the outdoor unit both the wide and narrow tubes of this ai...

Page 13: ...eferred to indoor unit MCAV72C5TA 0 00 0 10 0 20 0 30 0 40 0 50 0 60 0 70 0 80 0 90 20 25 30 35 40 45 Outdoor inlet air D B C Low pressure at wide tube service valve MPa 1 2 3 4 5 6 20 25 30 35 40 45...

Page 14: ...t MCAV92C5TA 0 00 0 10 0 20 0 30 0 40 0 50 0 60 0 70 0 80 0 90 20 25 30 35 40 45 Outdoor inlet air D B C Low pressure at wide tube service valve MPa 1 2 3 4 5 6 20 25 30 35 40 45 Outdoor inlet air D B...

Page 15: ...V122C5TA 1 2 3 4 5 6 7 8 9 10 20 25 30 35 40 45 Outdoor inlet air D B temp C Operating current A Indoor inlet air D B C 27 19 32 0 00 0 10 0 20 0 30 0 40 0 50 0 60 0 70 0 80 0 90 20 25 30 35 40 45 Out...

Page 16: ...00 1 90 1 78 1 64 CM 0 53 0 55 0 57 0 59 0 61 0 64 21 SHC 0 96 0 90 0 88 0 83 0 78 0 73 23 SHC 1 14 1 06 1 04 1 00 0 95 0 89 19 25 SHC 1 31 1 22 1 19 1 15 1 11 1 05 27 SHC 1 48 1 38 1 35 1 62 1 26 1 2...

Page 17: ...2 25 CM 0 80 0 84 0 87 0 90 0 93 0 97 21 SHC 1 32 1 24 1 20 1 14 1 07 0 99 23 SHC 1 56 1 46 1 42 1 36 1 29 1 22 19 25 SHC 1 79 1 67 1 63 1 58 1 51 1 43 27 SHC 2 02 1 88 1 85 2 04 1 73 1 65 29 SHC 2 2...

Page 18: ...9 2 94 CM 1 07 1 14 1 21 1 29 1 36 1 43 21 SHC 1 73 1 62 1 57 1 49 1 40 1 30 23 SHC 2 04 1 90 1 86 1 78 1 69 1 59 19 25 SHC 2 35 2 18 2 14 2 06 1 98 1 87 27 SHC 2 64 2 46 2 42 2 35 2 26 2 16 29 SHC 2...

Page 19: ...Amps A 0 120 0 280 4 500 4 900 Power input kW 0 027 0 063 1 030 1 120 NOTE Data referred to indoor unit MCAV92C5TA For other indoor unit models there could be some differences OUTDOOR UNIT GRV122C5TA...

Page 20: ...6 2 Electric Wiring Diagram 6 3 System Wiring Diagram 20...

Page 21: ...R D 28 Reyrieux BP 131 01601 Tr voux CEDEX France T l 04 74 00 92 92 Fax 04 74 00 42 00 R C S Bourg en Bresse B 759 200 728...

Reviews: