OUTDOOR UNIT:
GRF228R5TAA
COOLING
Indoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
performance at
Rating conditions
Running Amps.
A
0,40
0,67
8,13
9,20
Power input
Kw
0,086
0,144
1,820
2,050
Full load conditions
Running Amps.
A
0,40
0,67
9,93
11,00
Power input
Kw
0,086
0,144
2,270
2,500
Rating Conditions:
Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions: Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
HEATING
Indoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
performance at
Rating conditions
Running Amps.
A
0,40
0,67
8,43
9,50
Power input
Kw
0,086
0,144
1,920
2,150
Full load conditions
Running Amps.
A
0,40
0,67
9,93
11,00
Power input
Kw
0,086
0,144
2,270
2,500
Rating Conditions:
Indoor Air Temperature 20°C D.B.
Outdoor Air Temperature 7°C D.B. / 6°C W.B.
Full Load Conditions: Indoor Air Temperature 27°C D.B.
Outdoor Air Temperature 24°C D.B. / 18°C W.B.
NOTE: Data referred to indoor unit
MPAF228R5TAA
model.
For other indoor unit models there could be some differences.
Outdoor unit
230V 1-Phase 50 Hz
Outdoor unit
230V 1-Phase 50 Hz