1-2 Major Component Specifications
CA9FIB0R5IAA
Controller PCB
Part No.
Controls
Control circuit fuse
Remote Control Unit
Fan & Fan Motor
Type
Q'ty ……. Dia. and lenght
mm
Fan motor model…Q'ty
No. of poles…rpm (230 V, High / med / Low)
Running Amps (230 V, High / med / Low)
A
Power input (230 V, High / med / Low)
W
Coil resistance (Ambient temp. 25 °C )
Safety devices
Type
Operating temp. Open
°C
Close
Run capacitor
µF
VAC
Flap Motor
Type
Model
Rating
Coil resistance (Ambient temp. 25 °C )
Heat Exch. Coil
Coil
Rows
Fin pitch
mm
face area
m2
DATA SUBJECT TO CHANGE WITHOUT NOTICE
WHT-RED: 101
GRY-RED: 29
BLK-GRY: 63
2
Internal thermal protector
130 ± 10%
Automatic
0,258
SAC DCI IDU
4… 950 / 790 / 700
Aluminium plate fin / Copper tube
2
1,3
440
0,31 / 0,28 / 0,25
BRN-WHT: 19
Microprocessor
250 V - 3,15 A
1…. Ø 280 / L 166
72 / 63 / 58
BLU-BLK: 239
Centrifugal fan
BOM Y5S413B220 …1
SAC W-REM V3
400±7%
DC 12 V
Stepping motor
MP24Z2
5