12
XGT_User Manual
4.
Install the drop cables on the F-ports with 30 in/lbs (3.5 N-m) torque and install the hardline cables on the in-and output
with 40 in/lbs (4.5 N-m) torque.
2. Replacing the CM without any power loss using the MBBT
If a coupler module is broken, or you need a different directional coupling to be applied – the XGT tap range ensures minimal
installation time and extremely short downtime. By using the XGT- MBBT you can bypass the multitap with RF signals and
15A of current while maintenance is being preformed on the coupler module
.
1.
Pick your material – one new CM and one XGT-MBBT.
2.
Remove the faceplate from the tap (you can keep all the cables attached).