LMDA3726 Series 1.2 GHz Compact MDU Amplifiers
Installation Manual
Page 1 of 3
Lindsay Broadband’s exclusive, compact, multiple-dwelling unit (MDU) amplifier delivers reliable performance supporting DOCSIS
®
3.1 frequencies to 1.2 GHz.
The LMDA3726 series of amplifiers is designed for advanced HFC network installations in apartment buildings, hotels, schools, hospitals and similar facilities having
high RF amplification requirements. Designed with high gain, this two-way, upgradeable amplifier uses the latest 1.2 GHz GaAs-FET push-pull technology to provide
superior distortion performance and low noise. This amplifier can be mounted directly to a wall, and further reduces operational costs with increased heat dissipation
and low power consumption.
FEATURES
•
Fully meets the requirements of DOCSIS 3.1
•
Downstream frequency bandwidth extends to 1.2 GHz
•
Operating Temperature: -30°C to +55°C (-22°F to +131°F)
•
Forward gain 37 dB; reverse gain 26 dB
•
-20 dB external test points
•
GaAs-FET push-pull technology for high output levels with low distortions
•
Variable attenuators are designed to include a potentiometer - digital
signal attenuator combination to match excellent return loss performance
•
SCTE compliant F-type connectors
•
6 kV surge protection on all ports
•
Powering Options: HFC 40-90 VAC, 24 VDC, 100-240 VAC
•
Finned, diecast aluminum housing for heat dissipation
PRODUCT OVERVIEW
Part #
Power Socket Type
Frequency Range
LMDA3726-A-xx
100-240 VAC (N. America)
5-42 MHz / 54-1220 MHz
5-85 MHz / 102-1220 MHz
5-204 MHz / 258-1220 MHz
LMDA3726-B-xx
100-240 VAC (Europe)
LMDA3726-C-xx
40-90 VAC (HFC-powered)
CAUTION
Risk of electric shock. Do not open.
No serviceable parts inside. Refer servicing to qualified service personnel.
WARNING: To prevent shock hazard, do not expose this unit to rain or moisture. This apparatus shall not be exposed to dripping or splashing
water and no objects filled with liquids, such as vases, shall be placed on the apparatus.
WARNING: This product is a Class-I construction. Please ensure a connection to power source includes a protective earthing connection.
Remember to replace cover after adjusting. Cover must be in place for CE, safety and protection.
FUNCTIONAL SCHEMATIC