6
04/2019 - EN/V9
Technetix Group Limited
Product user manual
DBE-1200S
Chapter 2: DBE-1200S RF amplifier or optical node
1
17
15
16
12
14
11
12
15
4
8
7
3
2
5
6
10
12
15
13
14
9
15
Item No.
Description
1
Removable power supply
2
Main upstream amplifier module (one place)
3
Upstream bridger amplifier module (one place)
4
Upstream auxiliary plug-in JXP attenuator location
(can be used for other types of JXP plug-ins) (three places)
5
Digital control module
6
Digital control module USB connection port
7
Main downstream amplifier module (one place)
8
Downstream bridger amplifier modules (two places)
9
Downstream cable simulator JXP location
(can be used for other types of JXP plug-ins) (three places)
Item No.
Description
10
Input diplex filters; 42/54, 65/85, 85/102, 85/105
and 204/258 options available (one place)
11
Output diplex filters;42/54, 65/85, 85/102, 85/105 and 204/258
options available (three places)
12
Fuses (four places)
13
Input -20 dB test point (omnidirectional) (one place)
14
Output downstream -20 dB test point (upstream injection -20 dB
test point) (three places)
15
Field replaceable surge arrestors (four places)
16
Optional local powering port (mains or 65 VAC)
17
Optional DOCSIS Transponder
(Requires DBDCM-B-2 DOCSIS Control Module and cables)
DBE-1200S RF amplifier