OI: BK MIKRO 7
BK Mikro 7 Manual
Rev. 2.00 dated 20.01.2006
Page 17
3.1.6
Toggle switches
Using the six toggle switches arranged next to each other on the control unit front panel, the
following functions may be set.
Fig. 3-5: Control unit – Toggle switches
Note:
Setup on delivery:
All switches are toggled to the right !
When using scanner BK7RLSC: "Scanner" switch to the left !
"Scanning intensity" switch
Speed and force of scanner's wand in its scanning range.
For "Teach-in" and "Start" cycle, in case of a good message, they amount to:
"Scanning intensity"
Impact Forces
switch position
approx. 200 mN
approx. 500 mN
The values are valid for a wand of 150 mm length, measured on its scanning tip.
Note:
If this switch is in the "low" position, the lower impact force of the scanner will protect the
wand from wear and tear.
"Normally open contact / Normally closed contact" switch
Mode of operation for the two output relays (see section "Relay outputs").
"Object monitoring / Free space monitoring" switch
"O.K." result for
– finding an object (object monitoring) or
– not finding an object (free space monitoring) in the scanning window.
Note:
Free space monitoring is admissible only in combination with range setting by rotary
switches P1 and P2 and connected scanner BK7SC with toggle switch
set to " BK7SC".
Caution
O
R
F
L
High scanning intensity
Relay N.C.
(as normally closed contact)
Free space monitoring
Counter-clockwise travel
Large range of tolerance
Scanner TK7RL
Low scanning intensity
Relay N.O.
(as normally open contact)
Object monitoring
Clockwise travel
Low range of tolerance
Scanner TK7A
Summary of Contents for BK MIKRO 7
Page 2: ......