TechLogix Network TL-RKPS-01 User Manual Download Page 1

 

 

 

 

User Manual 

TL-RKPS-01 

Integrated Switching Power Supply 

 

 

 

 

 

 

 

 

 
 

All Rights Reserved 

Version: TL-RKPS-01_170525

 

Summary of Contents for TL-RKPS-01

Page 1: ...User Manual TL RKPS 01 Integrated Switching Power Supply All Rights Reserved Version TL RKPS 01_170525 ...

Page 2: ...ment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications It has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a commer...

Page 3: ...ure or install this product near water l Do not put any heavy items on the extension cable in case of extrusion l Do not remove the housing of the device as opening or removing housing may expose you to dangerous voltage or other hazards l Install the device in a place with fine ventilation to avoid damage caused by overheat l Keep the module away from liquids l Spillage into the housing may resul...

Page 4: ...ions 8 Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding plug A polarized plug has two blades with one wider than the other A grounding plug has two blades and a third grounding prong The wide blade or the third prong is provided for your safety If t...

Page 5: ... this equipment in a confined or building in space such as a book case or similar unit and remain a well ventilation conditions at open site The ventilation should not be impeded by covering the ventilation openings with items such as newspaper table cloths curtains etc 18 WARNING Only use attachments accessories specified or provided by the manufacturer such as the exclusive supply adapter batter...

Page 6: ...vel and reduce the amount of time listening at high levels Headsets should comply with EN 50332 2 requirements for GS certification 26 WARNING The mains plug appliance coupler direct plug in adapter is used as disconnect device the disconnect device shall remain readily operable or The all pole mains switch located on front panel is used as the disconnect device the switch shall remain readily ope...

Page 7: ...r to the presence of important operating and maintenance instructions in the literature accompanying the appliance 28 Protective earthing terminal The apparatus should be connected to a mains socket outlet with a protective earthing connection 29 Caution To prevent electric shock hazard replace grille CSA 60065 clause 5 3A ...

Page 8: ...nection Procedure 4 4 System Operations 5 4 1 Front Panel Buttons 5 4 2 RS232 Control 5 4 2 1 Installation uninstallation of RS232 Control Software 5 4 2 2 Basic Settings 5 4 2 3 RS232 Communication Commands 6 4 3 Web based GUI Control 11 4 3 1 Control Menu 12 4 3 2 Voltage Setting Menu 13 4 3 3 Network Menu 13 4 3 4 Password Menu 14 4 3 5 Web based GUI Update 15 5 Specification 16 6 Panel Drawing...

Page 9: ...ted as 5 12 24V DC via the TACT Switch on rear panel RS232 command or web based GUI 1 2 Features l Double input channel designed for ensuring the stable AC source l Total 12 output channels and each channel has three kinds of output voltage 5 12 24VDC can be selected l Output channels can be switch on off by via the front panel buttons RS232 commands or Web based GUI l Output voltage 5 12 24VDC ca...

Page 10: ...d the corresponding LED will turn green and keep on l Long press the button for 3 seconds or more to lock unlock the corresponding channel and then the corresponding LED will flash 3 times Note Pictures shown in this manual are for reference only different model and specifications are subject to real product 2 2 Rear Panel 1 2 3 C 24V DC 12V 5V SELECT AC100V 240V Tx Rx RS232 TCP IP 24V AC100V 240V...

Page 11: ...C 5 12 24V indicators l Green when the current selected output voltage is work normally l Blinking slowly when the current channel is closed l Blinking fastly when the current channel is short circuit or over voltage RS232 Serial port 3 Pin phoenix connector connect with a control device such as PC to control the product via RS232 commands TCP IP Ethernet port connect with PC to control the produc...

Page 12: ...C ports on rear panel Step2 Connect the PC to the RS232 port on rear panel Step3 Connect the PC to the TCP IP port on the rear panel Step4 Connect the power cables to the one or both of AC1 and AC2 input port AC100V 240V Tx Rx RS232 TCP IP 24V AC100V 240V AC1 AC2 DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V ...

Page 13: ... overvoltage protection control and it need to be turned on again via the corresponding output channel switching button on front panel l Restore Factory Defaults On rear panel simultaneously long press SELECT on channel 01 and channel 02 for 3 seconds or more the device will be restored to factory setting 4 2 RS232 Control Connect a PC to the RS232 port on the rear panel and then install the RS232...

Page 14: ...are able to send command in Command Sending Area 4 2 3 RS232 Communication Commands Communication protocol RS232 Communication Protocol Baud rate 9600 Data bit 8 Stop bit 1 Parity bit none Command Function Feedback Example All Switch on all output channels All Open All Switch off all output channels All Closed Parameter Configuration area Monitoring area indicates if the command sent works Command...

Page 15: ...x 5 12 24 y Output x V Status x When x NULL query the on off status of all output channels 01 Open 02 Closed 03 Closed When x 1 12 query the on off status of the output channel x x Open x Closed Save x Save the current on off status to Group x x 1 5 Save To F x Recall x Invoke the on off status of Group x x 1 5 If Group x has no data the feedback information F x no data If Group x has data the fee...

Page 16: ...n x NULL query all groups Out 01 02 03 04 05 06 07 08 09 10 11 12 Vm1 12 12 12 12 12 12 12 12 12 12 12 12 Vm2 XX XX XX XX XX XX XX XX XX XX XX XX When x 1 5 query the group x Out 01 02 03 04 05 06 07 08 09 10 11 12 Vm x 12 12 12 12 12 12 12 12 12 12 12 12 0911 Restore Factory Defaults Factory Default 9964 Query the IP address IP XXX XXX X XXX ChangeIP XXX XXX X XXX Change IP address Subnet Mask Ga...

Page 17: ...38400 57600 115200 When x NULL the default baud rate is 9600 Baud x not change Baud y change to x Lock x When x NULL lock all channels Locking all channel When x 1 12 lock the channel x Locking x channel Unlock x When x NULL unlock all channels Locking all channel When x 1 12 unlock the channel x Locking x channel LockKeyboard x When x 0 unlock the front panel Unlocking keyboard When x 1 lock the ...

Page 18: ...e digit 0 is used for padding For example FB 54 50 55 48 2D 50 53 55 31 32 00 00 00 20 00 00 FE TL RKPS 01 Note l After sending the Output x V y to change the output voltage the corresponding output channel will be switch off the command x should be sent to switch on this output channel again l After sending the LockKeyboard x to lock the front panel the device can be controlled via RS232 commands...

Page 19: ...lled via web based GUI It allows users to interact with the product through graphical icons and visual indicators 1 Connect a PC to the TCP IP port on the rear panel and set its network segment to the same as the default IP of the product 192 168 0 178 port No 4001 2 Type 192 168 0 178 in your browser it will enter the log in interface shown as below Same network segment as the product ...

Page 20: ...ntrol Menu Type user name user and password user default setting on the log in interface and then click Login to enter Control menu shown as below l Select the ON OFF to switch on off the output channel l Click the All On to switch on all output channels ...

Page 21: ... channels 4 3 2 Voltage Setting Menu Click Voltage Setting on the top of page to enter voltage setting menu shown as below In this interface you can select 5V 12V or 24V for each output channel 4 3 3 Network Menu Click Network on the top of page to enter network setting menu shown as below ...

Page 22: ...ynamic or static IP mode can be selected Under static IP mode IP address and subnet mask gateway can be set and make sure the IP addresses are different to avoid IP conflict 4 3 4 Password Menu Click Password on the top of page to enter password menu shown as below ...

Page 23: ...orts online update in http 192 168 0 178 100 Type the username and password the same as the GUI log in settings modified password will be available only after rebooting to log in the configuration interface After that click Administration at the source menu to get to Upload Program as shown below Select the desired update file and press Apply it will start upgrading then ...

Page 24: ...el 5V 12W 12V 15W 24V 15W Maximum output power consumption for single supply 110VAC 90W 220VAC 180W Maximum output power consumption for dual supply 180W Control Part Buttons Control Front Panel 01 12 total 12 buttons Rear Panel Total 12 TACT Switches named SELECT RS232 Control RS232 port 3 Pin phoenix connector Baud rate support 1200 2400 4800 9600 default 19200 38400 57600 115200 Web based GUI C...

Page 25: ...00V 240V Tx Rx RS232 TCP IP 24V AC100V 240V AC1 AC2 DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 24V DC 12V 5V SELECT 437 mm 357 mm 44 mm ...

Page 26: ... RS232 port Wrong RS232 communication parameters Type in correct RS232 communication parameters Fail or loose connection Make sure the connection is good Broken RS232 port Send it to authorized dealer for checking Cannot control the device by front panel buttons while can control it through RS232 port The front panel buttons are broken Send it to authorized dealer for repairing Cannot control the ...

Page 27: ...anel buttons web based GUI The device has already been broken Send it to authorized dealer for repairing If your problem persists after following the above troubleshooting steps seek further help from authorized dealer or our technical support ...

Page 28: ...ear l Use of supplies or parts not meeting our specifications l No certificate or invoice as the proof of warranty l The product model showed on the warranty card does not match with the model of the product for repairing or had been altered l Damage caused by force majeure l Non authorized service l Other causes which does not relate to a product defect l Delivery installation or labor charges fo...

Reviews: