• Check the evenness of the floor onto which the appliance is to be installed.
• The wall onto which the product is installed must not be made of wood or other flammable
materials.
• The required safety distance must always be observed.
• During operation, some parts of the stove (door, door handle, side walls) may heat up
strongly. For this reason, be extremely careful and take the required safety measures, espe-
cially in the presence of children, old people, disabled people, and animals.
• Never install the stove in bedrooms.
• When the stove is in operation, there will be a strong development of heat on the surfaces,
glass pane, door handle, and lines: These parts may be touched only with suitable protec-
tive equipment during operation.
• Keep the fuel and any flammable materials at an appropriate safety distance to the stove.
• The stove must not be fired in case of a broken glass pane.
• The installation site of the stove must have a sufficient air exchange.
• Symbols appearing on your product must not be removed or covered. Signs on the product
that are no longer legible must be replaced immediately.
Brief instructions and operation
These brief instructions provide an initial overview for the operation of the air controller of the
stove. Despite this, please read the complete instructions carefully.
• The stove has three air controllers.
According to which fuel you use, these air controllers absolutely must be adjusted as described
in the following.
The incorrect adjustment of the controllers can have wide-reaching consequences, for exam-
ple, the stove can be damaged due to overheating, the combustion is not clean, and the
desired burn-up time is not achieved!
• Controller 1: Secondary air controller in the door above the pane
• Controller 2: Rotary power controller behind the lower door
• Controller 3: Primary air slide controller on the ash box behind the lower door
When using wood/wood pellets as fuel: Unregulated open combustion
For heating-up, we recommend using a chimney or barbecue lighter with fine, dry wood.
• Controller 1: Completely open
• Controller 2: Position "O" closed (absolutely must be observed)
• Controller 3: Closed (absolutely must be observed)
Read the instructions for use before use
NOTICE!
Danger from product damage!
The ash box must ALWAYS be pushed completely (flush) into the provided opening
since otherwise primary air flows into the combustion chamber in an uncontrolled man-
ner and the stove no longer works properly!
GB
Ofen_477445.book Seite 49 Donnerstag, 5. Juni 2014 9:15 09
Summary of Contents for Nevio UNI-1964-L-GTS13-FA
Page 2: ...2 1 2 3 1 Ofen_477445 book Seite 2 Donnerstag 5 Juni 2014 9 15 09...
Page 127: ...127 RU Ofen_477445 book Seite 127 Donnerstag 5 Juni 2014 9 15 09...
Page 128: ...128 2 1 1 2 RU Ofen_477445 book Seite 128 Donnerstag 5 Juni 2014 9 15 09...
Page 133: ...133 3 2 3 RU Ofen_477445 book Seite 133 Donnerstag 5 Juni 2014 9 15 09...
Page 134: ...134 2 2 2 MAX 2 RU Ofen_477445 book Seite 134 Donnerstag 5 Juni 2014 9 15 09...
Page 135: ...135 2 25 30 25 30 20 3 2 0 15 C RU Ofen_477445 book Seite 135 Donnerstag 5 Juni 2014 9 15 09...
Page 136: ...136 2 3 2 3 0 RU Ofen_477445 book Seite 136 Donnerstag 5 Juni 2014 9 15 09...
Page 137: ...137 RU Ofen_477445 book Seite 137 Donnerstag 5 Juni 2014 9 15 09...
Page 138: ...138 1 1a 1b RU Ofen_477445 book Seite 138 Donnerstag 5 Juni 2014 9 15 09...
Page 140: ...140 RU Ofen_477445 book Seite 140 Donnerstag 5 Juni 2014 9 15 09...
Page 157: ...157 RU 1 2 24 3 Ofen_477445 book Seite 157 Donnerstag 5 Juni 2014 9 15 09...
Page 158: ...158 4 20 13109 97 Ofen_477445 book Seite 158 Donnerstag 5 Juni 2014 9 15 09...
Page 159: ...159 Ofen_477445 book Seite 159 Donnerstag 5 Juni 2014 9 15 09...