TECHFASS MREM 82 MTM-MF User Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

MREM 82 MTM-MF 

MREM 82 MTMVR-MF 

 

MIFARE

®

 & NFC reader modules for MTM panels 

User’s guide 

© 2018 – 2019, TECH FASS s.r.o., Věštínská 1611/19, 153 00 Prague, Czech Republic, www.techfass.cz, [email protected] 

(Date of release: 2019/06/03, valid for FW version 7.00) 

 

Summary of Contents for MREM 82 MTM-MF

Page 1: ...MTMVR MF MIFARE NFC reader modules for MTM panels User s guide 2018 2019 TECH FASS s r o Věštínská 1611 19 153 00 Prague Czech Republic www techfass cz techfass techfass cz Date of release 2019 06 03 valid for FW version 7 00 ...

Page 2: ...MREM 82 in MTM panel integrated in system APS mini Plus 11 5 Setting parameters of the reader module 12 5 1 Configurable parameters 12 5 2 Reader module parameters setting 13 6 Reader module functioning 13 6 1 Door Open function description 13 6 2 Current limit of OUT 1 and OUT 2 13 6 3 Function permanent door lock release according to a time schedule 14 6 4 Alarm states 14 6 5 Standard operating ...

Page 3: ...on needs to be installed The mobile phone can be used for identification instead of classic cards card emulation mode 2 1 MREM 82 MTM MF module The module is designed for installation into entry panel MTM of CAME audio and video systems and is supplied with brushed silver aluminum surface Pic 1 2 2 MREM 82 MTMVR MF module The module is designed for installation into entry panel MTMVR vandal resist...

Page 4: ...X MTM VR Black zamak Na požádání NREM 81 MTM EM APS 400 MTM Brushed aluminum 54481001 NREM 81 MTM TF APS 400 MTM Brushed aluminum 54481000 NREM 81 MTMVR EM APS 400 MTM VR Black zamak 54481011 Table 1b 125 kHz product version overview REM 81 Table 1b mentions just all the rest of the RFID module versions into panel MTM based on 125 kHz EM Marin Jablotron Links to these products are listed at the en...

Page 5: ... up Memory Cards 2 000 ID 2 programming cards Events 3 400 Time schedules 64 Inputs 1st input Logical potential free contact 2nd input Logical potential free contact Output Door lock 3 1x open collector 0V active max 1A 24V Alarm 1x open collector 0V active max 1A 24V Signalization 1x LED 1x PIEZO Tamper protection Optional connection to IN2 System communication interface RS 485 Alternative data c...

Page 6: ...chips You can download the application on Google Play for free Pic 3 Google Play and TF mobile ID 3 3 Mechanical design Pic 4 MREM 82 MTM MF Mechanical design Weight 122 g Operating temperature 25 70 C Humidity 5 95 non condensing IP code IP 54 IK code IK 07 IK 09 VR version Cable length 2 x 0 4 m Color MREM 82 MTM Silver brushed aluminum MREM 82 MTM VR Black zinc alloy zamak Dimensions Height x W...

Page 7: ...1 GND GND 12V 1 2 3 4 5 Table 4 Power supply cable wiring W1 B W0 A IN2 IN1 GND B A 6 7 8 9 10 11 12 Table 5 Data cable wiring 3 6 Wiring description Wiring description Color Purpose 1 Pink Output 2 open drain 1A Alarm output 2 Violet Output 1 open drain 1A Lock 3 Blue GND power supply 4 Blue GND power supply 5 Red 8 28 VDC 6 Brown green WIEGAND data 1 alternatively RS 485 7 White green WIEGAND da...

Page 8: ...flashing with 1s per Indicating door lock release Table 8 LED indication 3 9 Installation instructions Generally the noise can influence the reading functionality of the reader so it is recommended to check the place of installation if there could be some source of noise The reader uses passive RFID technology on 13 56 MHz frequencies which could be sensitive to RF noise sources either radiated no...

Page 9: ...it button input of the MTM panel 4 2 Simple connection of MREM 82 MTM MF and MTM IP with POE If there is a LAN switch with integrated POE the MTM panel and MREM 82 MTM MF can be both powered from POE The estimation of power requirement should be calculated for example if there are more MTM modular modules used In this case POE 802 3af does not have to provide enough power and POE 802 3at should be...

Page 10: ...Page 10 Pic 6 Utilization of POE power supply ...

Page 11: ...f APS mini Plus access control system backed up with a battery In this case the power supply of access control system is separated from the power supply of the intercom system to be able to control the door when the main power grid is off and the intercom is off Pic 7 Wiring of MREM 82 MTM MF as a part of battery power backed up system APS mini Plus ...

Page 12: ...xternal tamper tamper disabling function REX button Acoustic signalization time Forced door 0 255 s 30 s Acoustic signalization time Door ajar 0 255 s 0 s Acoustic signalization time APB alarm 0 255 s 0 s Signalization time Card alarm 0 255 s 30 s Antipassback function setting See chapter 6 10 Disabled Automatic summer time adjustment YES NO YES Release lock with REX button when tamper alarm activ...

Page 13: ...apsed see configuration table In case the toggle function of the door lock relay is set the door lock relay status is switched and the beeper is activated when not disabled when the Door Open function is activated The beeper stays active until the door is opened or the preset door lock release time has elapsed see configuration table The door lock relay status remains unchanged until another Door ...

Page 14: ...ws Via communication line statuses 1 2 3 4 By acoustic signal beeper statuses 1 2 3 Alarm signaling via communication line requires online running PC with relevant software suitable for online operation APS Administrator Two ways of acoustic signaling is carried out Steady signal tamper Intermittent signal forced door and or door ajar APB alarm Acoustic alarm signaling is stopped after a valid ID ...

Page 15: ...alarm state while signalizing Invalid ID 6 5 Standard operating modes The reader module can be in either online or offline operating mode The module s functionality is identical in both operating modes the events archive is read from the reader module s memory when the module goes online When a programming card is read while in either online or offline mode the module goes into programming mode 6 ...

Page 16: ...rting the last card the reader module goes back into standard operating mode Pic 5 a Inserting cards 6 6 2 Deleting cards from the reader s memory For deleting the cards from the reader module s memory use following steps Step 1 Step 2 Step 3 Read the programming card for deleting the reader goes into programming mode One by one read the cards which are to have their access revoked About 15 second...

Page 17: ...es into programming mode which is indicated by slow flashing of yellow LED Read the programming card for inserting 5 times in a row the reader will go into Deleting cards above or below mode indicated by fast flashing of yellow LED Read a card which is located in the module s memory right before or right after the card you wish to delete After this step the module quickly flashes with yellow LED S...

Page 18: ... adding and deleting cards should be stored in the table Following example shows correct usage of the programming cards and proper filing of the actions Inserting 5 new cards using the procedure from chapter 6 6 1 Read inserting programming card read cards 1 5 after 15 s the programming mode is exited create a table Pic 5 e Table after inserting 5 cards Card 3 gets lost Delete it using the card 4 ...

Page 19: ... in chapter 6 6 4 it is necessary to create a new filing table 6 7 ID expiration function This function is implemented since the FW version 5 0 It is possible to set an Expiration date for every ID stored in the module When the date occurs the ID becomes invalid expired The expiration evaluation is performed on every date change in the module s RTC and when the access rights are downloaded 6 8 ID ...

Page 20: ...ain before the timer elapses Time APB alarm is raised Open door after APB time alarm if the option is enabled the Door open function is performed after the Time APB alarm is raised 6 9 2 Zone Antipassback The Zone Antipassback is defined by enabling the option for the relevant address The Zone APB flag is set for the ID when passing at the reader module If a user uses the ID again when the Zone AP...

Page 21: ...rization mode the reader module has to be equipped with a MLO license 7 Simplified access rights evaluation The model of access rights contains time schedules and a table of holidays A block diagram for access right evaluation can be seen in Pic 6 Pic 6 Simplified access rights evaluation VALID UNKNOWN ID FOUND ACCESS DRIVEN BY TIME SCHED ACCESS ALWAYS GRANTED HOLIDAY ACCESS GRANTED FOR HOLIDAY AN...

Page 22: ...EM 82 MTM MF MREM 82 MTMVR MF WRE 82 MTM MF WRE 82 MTM MF NREM 82 MTM MF NREM 82 MTMVR MF 2014 53 EU RED 2014 30 EU EMCD dle RED 2014 35 EU LVD ČSN EN 62368 1 dle RED 2011 65 EU RoHS Nařízení ES č 1907 2006 REACH Tabulka 7 Legislation 11 Useful links 11 1 MIFARE NFC reader modules 13 56 MHz MREM 82 MTM MF MREM 82 MTMVR MF APS mini Plus system https www techfass com en products 95 product 1554 mrem...

Page 23: ...en products 95 product 1560 mrem 81 mtmvr em WRE 81 MTM EM WRE 81 MTMVR EM wiegand output https www techfass com en products 96 product 1385 wre 81 mtm em https www techfass com en products 96 product 1562 wre 81 mtmvr em NREM 81 MTM EM NREM 81 MTMVR EM APS 400 system https www techfass com en products 95 product 1384 nrem 81 mtm em https www techfass com en products 95 product 1561 nrem 81 mtmvr ...

Reviews: