Command Range
Description
X
0 – 150
Report Signal Level
This command responds with the current S-meter level.
This corresponds to (-140 to +10 dBm).
Command Range
Description
V
—
Report Firmware Version Number
Command Range
Description
J
—
Report All Operating Parameters
The receiver responds with all operating parameters
regardless of their current use or relation to the current
operating modes.
THE FOLLOWING ASTERISK COMMANDS ARE SUPPORTED
Command Range
Description
*CX
—
Stop Scanning and Return to Manual Mode
Ignored if scan isn't active.
Command Range
Description
*TSbsss
0 – 255
Request Scan Status
'b' is a single decimal number containing bit-encoded status
information:
Bit 0: Set if Scan is in Dwell-Time cycle.
Bit 1: Set if Dwell is set to infinite (Dwell time set to zero).
Bit 2: Set if Squelch is open (channel is active).
Bit 3: Set if running MScan. Cleared if running PScan.
Bit 4: Set if Scan (MScan or PScan) is active. Cleared
otherwise.
Bit 5: Set if Scan is in Dead-Time cycle.
Bit 6: Set if Scan is in Gaze-Time cycle.
Bit 7: Set if Scan is in Pause state.
Command Range
Description
*Rn
0, 1
Select Remote mode
0: Set Local Mode.
1: Set Remote Mode.