background image

Installation Instructions for

920E3

-

LED AE

Round or Square Chicago Plenum Adjustable Housing
with

Lamp

Emergency Battery Backup and LED

E3_-L_AE

1.4

1

LED ROUND SQUARE

-

/

Install the Housing with Adjustable Bars

1A

BREAK OFF

AND DISCARD

¾” or thicker

½” to ¾”

LEAVE TAB

IN PLACE

Keep Tab for ceiling ½” to ¾” thick.

When using adjustable hanger bars with ½” to ¾” thick
ceilings, leave the tab of the hanger bars in place.

Break off Tab for ceiling ¾” or thicker.

When using adjustable hanger bars with ¾” or thicker
ceilings, remove the tab by bending it at the perforation.

1

NOTE:

Skip this section if installing the housing

with butterfly brackets.

HOUSING CLASP

HOUSING

1B

INNER ADJUSTABLE BAR

OUTER ADJUSTABLE BAR

TAB

STOP POINT

3

3

NAIL

2

2

3

4

Slide the inner adjustable bar completely through the
three housing clasps. Make sure the nail is on top.

Slide and push the outer adjustable bar completely onto
the inner adjustable bar so that the tab clicks into place
behind the stop point. This will prevent the adjustable bars
from coming apart.

Repeat steps 2 & 3 for the other side of the housing.

G

P

I

:

ENERAL RODUCT NFORMATION

This product is suitable for indoor locations.

This product can be dimmed with a standard electronic dimmer.

This instruction shows a typical installation.

CAUTION RISK OF FIRE

-

This product must be installed in accordance with the

applicable installation code by a person familiar with the

construction and operation of the product and the

hazards involved.

Use minimum 90°c supply conductors.

1C

COLLAR

NAIL

JOIST

NAIL

5

5

6

6

NOTE:

The adjustable bars can be mounted to

joists that are spaced 16" - 24" apart.

Align the bottom of the end plates with the bottom of the
ceiling joists.

Level the adjustable bars and, with a hammer, tap the nails
completely into the joists to secure the adjustable bars in
place.

5

6

5

6

Summary of Contents for ELEMENT E3-L AE Series

Page 1: ... the nail is on top Slide and push the outer adjustable bar completely onto the inner adjustable bar so that the tab clicks into place behind the stop point This will prevent the adjustable bars from coming apart Repeat steps 2 3 for the other side of the housing G P I ENERAL RODUCT NFORMATION This product is suitable for indoor locations This product can be dimmed with a standard electronic dimme...

Page 2: ...able bars TIP Notches in collar can be used to align multiple housings using a laser or string BUTTERFLY BRACKET COLLAR WING NUT 1 2 NOTCH Connect Power to the Housing Push up on the tabs on the electrical box and remove the electrical box cover Install the conduit to the housing electrical box Run the power line wires into the housing electrical box 1 3A TABS ELECTRICAL BOX COVER 1 1 CONDUIT 2 3 ...

Page 3: ... back ring from the flexible conduit Replace the back ring onto the port so the end of the wing screws are properly placed in the two blind holes Replace and tighten the 6 32 screws to secure the back ring onto the test switch port Keep the test switch port assembly in a safe place while the drywall is being installed 3 2 2 BACK RING TEST SWITCH PORT 6 Prepare the Test Switch Port NOTE When a fixt...

Page 4: ... the flexible conduit out of the 1 9 16 hole Unscrew the 6 32 screws and remove the back ring Screw the back ring from the face with two holes to the flexible conduit Unscrew the cap from the test switch port 5 3 4 2 2 3 4 5 6B Connect the red and black wires in the test switch port to the same color wire in the flexible conduit using wire nuts 6 6 6 6C LE NS ORIE NTA TION GUID ES LE NS ORIE NTA T...

Page 5: ...6 32 set screws to secure the back ring onto the test switch port Push the test switch port completely into the hole WING SCREW 8 9 8 7 8 9 6D Replace and tighten the cap 11 CAP 11 6F WING WING SCREW WING SCREW PHILLIPS SCREWDRIVER WING 10 Tighten the two phillips screws an electric screwdriver will help until the wings secure the test switch port into the hole 10 6E ...

Page 6: ...SS TO UNLOCK TILT LENS LOCK 8 32 SCREW 8 32 SCREW Secure the plaster ring in place with the two provided flat head 8 32 screws Make sure that the screws penetrate through the drywall into the housing screw holes 3 3 3 3 3 NOTE Do not overtighten the screws Overtightening may bend the plaster ring causing the plaster surface to come away from the drywall 6 LENS LOCK LENS LOCK Plug the collar with t...

Page 7: ...ever by pressing where indicated using a finger or screwdriver and position the assembly until the desired angle is reached NOTE Lamp housing can tilt 40 vertically Lock intervals are 2 5 apart INDICATOR 2 2 0 10 20 30 40 o o o o o TILT ADJUSTMENT LEVER PRESS TO UNLOCK TILT ROTATION LOCK 3 4 NOTE Lamp housing can rotate 361 horizontally 3 Pull the rotation lock down to unlock the lamp housing Rota...

Page 8: ...orizontal Alignment Guides 2 2 Install the Lenses Optional LENS HOLDER Place lenses max 2 optional inside the lens holder 1 LENSES 9A 9B 9C SAVE THESE INSTRUCTIONS 7400 Linder Ave Skokie 60077 IL 847 410 4400 www element lighting com 2019 Tech Lighting L L C All rights reserved The Element graphic is a registered trademark of Element Element reserves the right to change specifications for product ...

Reviews: