Summary of Contents for ST-280

Page 1: ...Tech 1...

Page 2: ...ration of the Controller 8 IVa Operating Principle 8 IVb Main Screen Description 8 V Controller Functions Menu Options 12 VI a Time 14 VI b Securities 15 VI c Screen 16 VI d Weekly Control 17 VI e Boi...

Page 3: ...eld liable for damage caused by negligence WARNING Live electrical device Before any activities related to power supply connecting wires device installation etc you must ensure that the regulator is n...

Page 4: ...n of the regulator and modulation of its parameters An additional advantage is the possibility to load photos to the controller s memory which will be displayed as a screensaver The ST 280 room regula...

Page 5: ...the relevant qualifications WARNING There is a danger of fatal electrical shock from touching live connections You must disconnect the electrical connection and protect against accidental connection b...

Page 6: ...uts in accordance with colours of wires The cable is then connected to RJ12 connector which you should plug into the regulator power supply the place of connection is marked on the scheme as point 2 t...

Page 7: ...ordance with colours of wires This cable is then connected to the RJ12 connector and should be plugged into the v2 module the place of connection is marked on the scheme as point 2 there is an additio...

Page 8: ...es etc IVb Main Screen Description The controller is equipped with a large touch screen display The main screen displays the current state of basic parameters for the boiler Depending on the user s se...

Page 9: ...of the valve not being installed the room regulator will display an icon 9 Boiler 1 temperature current and set clicking the screen in this area will switch you to the menu which enables you to introd...

Page 10: ...on the main controller 6 Current room temperature 7 Current time and date 8 Right parameters panel 9 Buttons allowing change of active view of parameters panel 10 Access to the controller menu 11 Lef...

Page 11: ...s panel it is possible to change the set temperature of the boiler Valves data panel View of the current temperature and set temperature of valve 1 2 3 or 4 after clicking on this panel it is possible...

Page 12: ...r after clicking on this panel it is possible to change the pumps operation mode A selection can be made from among the following modes Home heating Priority parallel pumps summer mode with additional...

Page 13: ...Screen View Panels Screen Installation Screen Night from Hour Day from Hour Brightness During the Day Brightness at Night Weekly control Activated Disabled Settings Boiler Control Submenu Subject to...

Page 14: ...ser to set the current time according to which the regulator will then operate Date This function allows the user to set the current date according to which the regulator will then operate Alarm clock...

Page 15: ...ich the alarm clock is to be activated Controller screen view at the time of activation of the alarm clock VI b Securities After clicking on the Securities icon on the main menu you will see the panel...

Page 16: ...creen Time out after expiration of the set idle time the screen will switch to stand by function Import of Photos Any photos you want to import to the controller s memory must be first prepared by mea...

Page 17: ...ss during the day and at night VI d Weekly Control This function allows you to change the set temperature of the room in a day night cycle You can set each day you can set the device to change to a sp...

Page 18: ...ller between Home heating Priority parallel pumps summer mode More detailed descriptions of these operating modes can be found in the operation manual for the boiler controller Submenu for the pellet...

Page 19: ...de the room and in accordance with the schedule of the boilers daily operations The current temperature inside the room is the priority for boiler under operation in this mode if the temperature in th...

Page 20: ...for changing the language for the user VI g Information about the Operating Program By clicking on this icon the display will show the boiler manufacturer s logo along with the software version VI h...

Page 21: ...selection is made the Boiler control submenu will be changed I Alarms The ST 280 room temperature regulator will signal all alarms generated by the main controller When the alarm activates the room re...

Page 22: ...g provisions of Low Voltage Directive LVD 2006 95 EC the Act of 13th April 2007 on Electromagnetic Compatibility Official Journal 07 82 556 implementing provisions of Directive EMC 2004 108 EC and the...

Page 23: ...y received a registry number assigned by the Chief Inspector of Environmental Protection The symbol of a crossed out disposal bin on the product means that the product must not be thrown out to genera...

Page 24: ...ST 280 user s manual 24...