EU DECLARATION OF CONFORMITY
Hereby, we declare under our sole responsibility that
EU-F-4z v1
manufactured by TECH, head-quartered in Wieprz Biała Droga 31, 34-
122 Wieprz, is compliant with Directive 2014/35/EU of the European
Parliament and of the Council of 26 February 2014 on the harmonisation
of the laws of Member States relating to the making available on the
market of electrical equipment designed for use within certain voltage
limits (EU OJ L 96, of 29.03.2014, p. 357), Directive 2014/30/EU of the
European Parliament and of the Council of 26 February 2014 on the
harmonisation of the laws of Member States relating to electromagnetic
compatibility (EU OJ L 96 of 29.03.2014, p.79), Directive 2009/125/
EC establishing a framework for the setting of ecodesign requirements
for energy-related products as well as the regulation by the MINISTRY
OF ENTREPRENEURSHIP AND TECHNOLOGY of 24 June 2019 amending
the regulation concerning the essential requirements as regards the
restriction of the use of certain hazardous substances in electrical
and electronic equipment, implementing provisions of Directive
(EU) 2017/2102 of the European Parliament and of the Council of 15
November 2017 amending Directive 2011/65/EU on the restriction of
the use of certain hazardous substances in electrical and electronic
equipment (OJ L 305, 21.11.2017, p. 8).
For compliance assessment, harmonized standards were used:
PN-EN IEC 60730-2-9:2019-06, PN-EN 60730-1:2016-10
.
Wieprz, 03.12.2020
SAFETY
Before using the device for the fi rst time the user should read the
following regulations carefully. Not obeying the rules included in
this manual may lead to personal injuries or controller damage.
The user’s manual should be stored in a safe place for further
reference. In order to avoid accidents and errors it should be
ensured that every person using the device has familiarized
themselves with the principle of operation as well as security
functions of the controller. If the device is to be sold or put in a
diff erent place, make sure that the user’s manual is there with
the device so that any potential user has access to essential
information about the device.
The manufacturer does not accept responsibility for any injuries
or damage resulting from negligence; therefore, users are obliged
to take the necessary safety measures listed in this manual to
protect their lives
and property
.
WARNING
•
The device should be installed by a qualified person.
•
The regulator is not intended to be used by children.
•
Any use other than specified by the manufacturer is
forbidden.
USER’S MANUAL
EU-F-4z v
1
EN
WARNING
•
Risk of fatal electric shock from touching live connections. Before
working on the controller switch off the power supply and prevent
it from being accidentally switched on.
•
Incorrect connection of cables may lead to controller damage.
We are committed to protecting the
environment. Manufacturing electronic
devices imposes an obligation of providing
for environmentally safe disposal of used
electronic components and devices. Hence,
we have been entered into a register kept
by the Inspection For Environmental
Protection. The crossed-out bin symbol on
a product means that the product may not
be disposed of to household waste
containers. Recycling of wastes helps to
protect the environment. The user is
obliged to transfer their used equipment to
a collection point where all electric and electronic components.
TECHNICAL DATA
Power supply
230V ±10%/50Hz
Max. power consumption
0,5W
Potential-free cont. nom. out. load
230V AC / 0,5A (AC1) *
24V DC / 0,5A (DC1) **
Humidity measurement range
10-95% RH
Room temperature adjustment range
50C ÷ 350
C
* AC1 load category: single-phase, resistive or slightly inductive AC load.
** DC1 load category: direct current, resistive or slightly inductive load.
The pictures and diagrams are for illustration purposes only.
The manufacturer reserves the right to introduce some changes.
DESCRIPTION
The EU-F-4z v1 room regulator is intended for controlling the heating
device. Its main task is to maintain the pre-set room temperature by
sending a signal to the heating device when the room temperature has
been reached.
Functions of the regulator:
•
Maintaining pre-set room temperature
•
Manual mode
•
Day/Night mode
•
Weekly control
•
Floor heating control (optional - an additional temperature sensor
is necessary)
Controller equipment:
•
Touch buttons
•
Front panel made of glass
•
Built-in temperature and humidity sensor
•
Intended to be mounted in a frame
Current temperature is displayed on the screen. Hold the EXIT button to
display current humidity.
Use
EXIT
to activate weekly control or day/night mode and to
deactivate manual mode. In the controller menu, use this button
to confirm new settings and return to the main screen view.
Use
to activate manual mode and decrease the pre-set temperature
value. In the controller menu, use this button to adjust parameter
settings.
Use
to activate manual mode and increase the pre-set temperature
value. In the controller menu, use this button to adjust parameter
settings.
Use
MENU
– to enter the controller menu. While editing parameters,
press MENU to confirm changes and move on to edit another parameter.
EXIT
display
MENU