SAFETY 

Before using the device for the first time the user should read the following regulations carefully. Not obeying the rules 
included in this manual may lead to personal injuries or controller damage. The user’s manual should be stored in a safe 
place for further reference. 

 In order to avoid accidents and errors, it should be ensured that every person using the device has familiarized themselves 
with the principle of operation as well as security functions of the controller. If the device is to be sold or put in a different 
place,  make  sure  that  the  user’s  manual  is  stored  with  the  device  so  that  any  potential  user  has  access  to  essential 
information about the device. 

The manufacturer does not accept responsibility for any injuries or damage resulting from negligence; therefore, users 
are obliged to take the necessary safety measures listed in this manual to protect their lives and property. 

       

WARNING 
 
 

 

High  voltage!  Make  sure  the  regulator  is  disconnected  from  the  mains  before  performing  any  activities 
involving the power supply (plugging cables, installing the device etc.) 

 

The device should be installed by a qualified electrician. 

 

The regulator should not be operated by children. 

 

WARNING 

 

 

The device may be damaged if struck by a lightning. Make sure the plug is disconnected from the power 
supply during storm. 

 

Any use other than specified by the manufacturer is forbidden. 

 

It is recommended to periodically check the condition of the device. 

 
 

Changes  in  the  merchandise  described  in  the  manual  may  have  been  introduced  subsequent  to  its  completion  on 
09.02.2021. The manufacturer retains the right to introduce changes to the structure or colours. The illustrations may 
include additional equipment. Print technology may result in differences in the colours shown.  

 

We are committed to protecting the environment. Manufacturing electronic devices imposes 
an obligation of providing for environmentally safe disposal of used electronic components 
and  devices.  Hence,  we  have  been  entered  into  a  register  kept  by  the  Inspection  for 
Environmental Protection. The crossed-out bin symbol on a product means that the product 
may not be disposed of to household waste containers. Recycling of waste helps to protect 
the environment. The user is obliged to transfer their used equipment to a collection point 
where all electric and electronic components will be recycled. 

 

 

 

Summary of Contents for EU-297 v3

Page 1: ...EU 297 v3...

Page 2: ...ice description 11 1 Main screen description 12 VII Controller functions 12 1 Block diagram main menu 13 1 1 Clock 13 1 2 Pre set day temperature 13 1 3 Day from 14 1 4 Pre set night temperature 14 1...

Page 3: ...ce etc The device should be installed by a qualified electrician The regulator should not be operated by children WARNING The device may be damaged if struck by a lightning Make sure the plug is disco...

Page 4: ...perature is below the pre set value The EU 297v3 controller functions Maintaining pre set room temperature Manual mode Day night mode Control of the floor sensor Controller equipment Touch buttons Fro...

Page 5: ...ed person The room regulator should be connected to the heating device with a two core cable When connecting devices with over 1A power a contactor must be used Optionally an additional sensor can be...

Page 6: ...TECH 6 1 INSTALLATION OF THE REGULATOR BATTERIES...

Page 7: ...powered with batteries it is recommended to check the batteries from time to time and replace them once every heating season 2 INSTALLATION OF THE REGULATOR POWER SUPPLY 230V The room regulator may b...

Page 8: ...TECH 8...

Page 9: ...EU 297 9 The room regulator should be connected to the heating device with a two core cable The cable connection of both devices is shown in the diagram below heating device...

Page 10: ...vailable the floor sensor must be enabled in the controller menu 2 OPERATION MODES The room regulator may operate in one of the following operation modes Day night mode In this mode the pre set temper...

Page 11: ...ton to display the room temperature floor temperature or to disable manual mode 3 press this button to decrease the edited value 4 press this button to increase the edited value 5 MENU button hold thi...

Page 12: ...heating 9 Current temperature 10 Button lock 11 Pre set temperature VII CONTROLLER FUNCTIONS The user navigates in the menu structure using touch buttons EXIT and MENU In order to edit particular par...

Page 13: ...t press MENU to move to the next parameter minutes 1 2 PRE SET DAY TEMPERATURE In order to define the pre set day temperature press MENU button until a flashing icon appears on the screen Use or to se...

Page 14: ...to define the exact time of entering the night mode To configure this parameter press MENU until a flashing icon appear on the screen Use or to set the time of night mode activation 1 6 HYSTERESIS Roo...

Page 15: ...he tolerance for the maximum and minimum temperature The settings range is from 0 2 C to 5 C If the floor temperature exceeds the maximum temperature the underfloor heating will be disabled It will be...

Page 16: ...in the Menu 2 1 COOLING HEATING This icon informs about the room heating or cooling to reach the pre set temperature These messages are displayed alternately cooling or heating 2 2 BUILT IN SENSOR CAL...

Page 17: ...ttons to set the desired correction To confirm press the MENU button confirm and go on to edit the next parameter 2 4 SOFTWARE VERSION After pressing the MENU button the user may check the software ve...

Page 18: ...of 29 03 2014 p 79 Directive 2009 125 EC establishing a framework for the setting of ecodesign requirements for energy related products as well as the regulation by the MINISTRY OF ENTREPRENEURSHIP A...

Page 19: ...EU 297 19...

Page 20: ...TECH 20...

Reviews: