14
7.2
Model LT14 (plastic)
Fix the lower half of the level gauge to the installation. The mobile flange-group (1) allows
adjusting its anchoring height.
Remove the adhesive tape from the lower glass tube (6) and loosen the 3 screws DIN933
M5 x 30 (5) without removing the nuts (3).
In case there is not enough space to introduce the float (7) through the lower part of the
gauge body once the assembly has been completed, the float must be in its correct position
inside this lower half at the time of installation.
NOTE: The clamp (2) that fixes the guide-support (4) should never be loosened.
DETAIL A
Installation
connections