TECALEMIT 104123700 Operating Manual Download Page 1

 

T

ra

n

sl

a

ti

o

n

 o

th

e

  

o

ri

g

in

a

o

p

e

ra

ti

n

g

 m

a

n

u

a

l

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating manual 

Visconet II 

 

 

Item-No.: 104123700, 104133701, 104123702, 104143701, 104163700, 

   104173701 

 

Summary of Contents for 104123700

Page 1: ...Translation of the original operating manual Operating manual Visconet II Item No 104123700 104133701 104123702 104143701 104163700 104173701 ...

Page 2: ...ficient knowledge of the operating manual Copyright HORN GmbH Co KG All rights reserved Text graphics and layout copyright protected Reproduction and copying including in part only permitted with written permission Technical changes reserved Service Hotline 49 1805 900 301 0 14 Min on the German landline network Mobile telephone max 0 42 Min service tecalemit de Document No 44 1338 101 E As of 10 ...

Page 3: ...8 2 4 3 Diagram III Visconet II M Visconet II M F 8 3 Assembly instructions 9 3 1 Place of installation 9 3 2 Assembly 9 3 3 Option flow meter 9 4 Operation 10 4 1 Commissioning and re commissioning 10 4 2 Normal operation 10 4 3 Flow meter optional 10 5 Dismantling 11 6 Fault display What to do if 11 7 Maintenance 12 7 1 Leak test 12 7 2 Discharge hose 12 7 3 Fuse 12 7 4 Cleaning the system 12 8 ...

Page 4: ...ids listed and the purpose described Using the machine for any other purpose would constitute inappropriate use The manufacturer is not responsible for any loss arising as a result of this the risk for this is borne only by the operating company Organisational measures This operating manual should always be kept readily available at the site of operation Each person concerned with the assembly com...

Page 5: ...ices for flammable and or water endangering substances During such works appropriate tools are to be used avoid sparking Before any kind of work on the device all fuel lines are to be completely emptied and aerated Do not make any changes Modifications or additions to the device which may affect the safety cannot be carried out without consent of the manufacturer Exclusively genuine spare parts ma...

Page 6: ...r supply The Visconet II must not be operated with flammable or explosive liquids with a flash point of below 55 C hazard classes AI AII and B Liquids with a flash point above 55 C hazard class A III must not be transported if they are heated beyond their flash point Operation in explosion risk areas is not permitted There is a risk of explosion 2 3 Product versions Item No Product Features 104 12...

Page 7: ...Input capacity 1 22 kW 0 64 kW Current 5 3 A 2 8 A Connecting cable 2 m Zero delivery pressure 4 5 bar 65 25 psi 2 0 bar 29 0 psi Nominal pump capacity see diagram I to III Max viscosity 2000 mPas 1000 mPas Min viscosity 100 mPas Drum thread G 2 Nozzle hose DN 19 x 4000 mm Suction head 840 mm Duration of operation 100 Weight 13 5 kg VISCONET II F VISCONET II M F 14 0 kg ...

Page 8: ...8 44 1338 101 E Visconet II 2 4 1 Diagram I 2 4 2 Diagram II Visconet II Visconet II F 2 4 3 Diagram III Visconet II M Visconet II M F ...

Page 9: ... Lay sealing on the barrel thread and connect pump with the enclosed screws M 10x35 high tension and hexagonal nuts M 10 Screw discharge hose 3 with the external thread G1 into the exit of the pump Screw other end of the discharge hose into the hose swivel 4 After mounting please test the connections for leakages 3 3 Option flow meter When a flow meter is in scope of supply please connect the G1 s...

Page 10: ... Normal operation Avoid dry running 1 min With the nozzle closed and the pump filled with medium it may be operated for max 1 min since otherwise this can lead to excessive heating and pump vane damage After the filling process the nozzle must be replaced in its nozzle holder The discharge hose should not remain lying on the ground in order to prevent damage to it e g by driving over it A defectiv...

Page 11: ...e the liquid The tank is empty The suction line and all screw joints on the suction side are to be checked for leaks and resealed if necessary the pump isn t to be switched on The mains plug is not plugged in The cable is damaged the pumping capacity is too low Very cold or viscous liquids can only be pumped with difficulty the delivery rate is correspondingly low possibly the temperature of the l...

Page 12: ...e Visconet II the motor is protected by a thermal cut out in the motor winding which resets itself after the motor cools down 7 4 Cleaning the system In the event of superficial fouling clean the device carefully with suitable materials use no corrosive cleaning materials Flush with diesel to clean the interior parts and pipes 8 Disposal The device is to be emptied completely and the liquids prope...

Page 13: ...44 1338 101 E Visconet II 13 9 Declaration of conformity ...

Page 14: ...14 44 1338 101 E Visconet II ...

Page 15: ...44 1338 101 E Visconet II 15 ...

Page 16: ...16 44 1338 101 E Visconet II HORN GmbH Co KG Munketoft 42 24937 Flensburg Germany T 49 461 8696 0 F 49 461 8696 66 www tecalemit de info tecalemit de ...