6-5
6. DIAG. TEST OPERATION
EO18-33007
#
Item
Contents
(11)
Threshold manual fine adjustment for
0.0V to 4.0V
the black mark sensor
(12)
Threshold manual fine adjustment for
0.0V to 4.0V
the feed gap sensor
(13)
Character
PC-850:
PC-851
PC-1252
LATIN9
PC-852:
PC-855
PC-1253
Arabic
PC-857:
PC-1250
PC-1254
PC-8:
PC-1251
PC-1257
Font zero
0:
No slash used.
0:
Slash used.
(14)
Control code
AUTO:
Automatic selection
ESC LF NUL:
ESC LF NUL mode
{ l }:
Mainframe mode
1B 1C 1D:
Manual
(15)
Ribbon type
TRANS.:
Transmissive ribbon
NON TRANS.:
Non-transmissive ribbon
1) Maintenance Counter
6.2 SELF TEST MODE
#
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
Count Condition
Counted when the feed motor drives to feed, print and issue the
media. (Counted also during ribbon save operation and back
feed.) [See NOTE 2.]
Counted while printing. (Feeding and issuing media, and ribbon
saving operation are not counted.) [See NOTE 2.]
Counts every cut. [See NOTE 3.]
Counts every up and down of the print head using the solenoid
for ribbon save operation. (Up+Down=1 count) [See NOTE 3.]
Counts when the ribbon motor drives to feed, print and issue the
media. (The driving time is not counted during ribbon saving
operation, but is during back feed.) [See NOTE 4.]
Counted during ribbon saving operation. [See NOTE 4.]
Counted when a parity, overrun or framing error occurs. [See
NOTE 5.]
Counted when a zero-dividing error occurs or undefined command
is retrieved.
Counts the number of times the power restores while the CPU is
busy after reset.
Item
Total media distance
covered
Media distance covered
Print distance
Cut count
Head up and down count
Ribbon motor driving time
Solenoid driving time
RS-232C hardware error
count
System error count
Momentary power failure
count
Range
0.0 to 3200.0
km
0.0 to 200.0 km
0.0 to 200.0 km
0 to 1000000
times
0 to 2000000
times
0 to 2000
hours
0 to 1000
hours
0 to 255 times
0 to 15 times
0 to 15 times
NOTES:
1. Item from (2) through (10) are initialized to “0” after RAM clear.
2. If the distance is 5.5 m or less, it is rounded down and no data is added to the memory
at power off.
3. If the count is 31 counts or less, it is rounded down and no data is added to the memory
at power off.
4. If the driving time is 27 sec. or less, it is rounded down and no data is added to the memory
at power off.
5. When a sent command results in an error, the same number as the data capacity of the
command is counted by byte.
2) Parameters
Summary of Contents for B-880 series
Page 3: ...TEC Thermal Printer B 870 880 QQ SERIES Owner s Manual ...
Page 35: ......
Page 36: ...PRINTED IN JAPAN EO1 33017 ...
Page 56: ......
Page 57: ......
Page 58: ...PRINTED IN JAPAN EO10 33008 ...
Page 146: ...6 59 6 DIAG TEST OPERATION EO18 33007 Fig 6 25 Bar code AUTO PRINT Fig 6 24 ...
Page 176: ......
Page 177: ......
Page 178: ...PRINTED IN JAPAN EO18 33007 ...
Page 179: ......
Page 180: ......