2-6
EO18-33007
2. MAJOR UNIT REPLACEMENT
6) Insert piled 10 pieces of tag paper of 8 inches (203.2 mm) in width, 0.16 mm in thickness (I-BEST-
S is recommended) between the print head and the platen. Then turn the head lever to the LOCK
position.
7) Press and hold the link against the solenoid, and then press and fit the solenoid unit sungly to the
link. Secure the solenoid unit with the screws.
8) Reassemble in the reverse order of removal.
Spring Pin
Solenoid
Head Up Link
Link
Press
Print Head
Paper Thickness: 1.6 mm
Platen
Solenoid Unit
Fig. 2-10
Fig. 2-9
Press
2.5 REPLACING THE SOLENOID
3) Remove the two SM-3 x 6B screws each from the solenoid units (L) and (R) to detach the solenoid.
4) Replace the solenoid and attach it to the solenoid attaching plate. Be careful of the differences in
length of the solenoid cables when installing the solenoid.
5) Assemble the solenoid unit so that the head up link engages the spring pin.
NOTE: Make sure to remove any dust that appears during removal or installation because it may affect
the print quality.
CAUTION:
Take care to orient the screws so that they are vertically aligned with the solenoid attaching plate.