TEC-63062-1 AutoCAN-Fv6

Function

Description

19

Transmission 

Condition

A constant level signal is formed if the transmissionhandle is set to the pre-

programmed position (P, R, N, D 1). For robotized transmission, the following 

positions can be programmed: R, N, D 1. For mechanical transmission, only 

R position is available.

20

Vehicle moves

A constant level signal is formed if the vehicle speed has exceeded a certain 

threshold value (this value varies from vehicle to vehicle, but lies within 5 – 10 

km/h).

21

Front parking sensors 

activation

A constant level signal is formed for activating the front parking system 

sensors

22

Rear parking sensors 

activation

A constant level signal is formed for activating the rear parking system sensors.

23

Parking Distance 

Control System LED 

output

It is used for indicating the PDC system condition.

• If the parking sensors work according to Activation on rear gear or Activa-

tion on rear gear with priority of switching off algorithm, the LED is ON 

when the sensors are active.

• If the parking sensors work according to Activation on speed, the LED is

ON when the sensors are not active.

24

Motion speed

A pulse signal is formed with pulse sequence frequency proportional to the 

vehicle speed. 1 imp/sec corresponds to a speed of 1 km/h. The signal is 

designed for determining estimated and not the exact speed.

25

Brake

A constant level signal is formed with the brake pedal pressed.

26

Handbrake

A constant level signal is formed when the vehicle is put on the handbrake.

27

External lights

A constant level signal is formed with the external lights on.

28

Timer Channel 

(Comfort)

A constant level signal is formed within a certain time (from 10 to 60 sec.) 

after arming the vehicle. The time is set in 10-second intervals.

29

Vehicle distance run

A pulse signal is formed with pulse sequence frequency proportional to the 

vehicle distance run. 1imp/sec corresponds to 5 meters run

30

Right turn signal

A pulse signal is formed with pulse sequence frequency proportional to pulse 

frequency of the vehicle right turn signal.

31

Left turn signal

A pulse signal is formed with pulse sequence frequency proportional to pulse 

frequency of the vehicle left turn signal.

32

Upper beam

A constant level signal is formed when the upper beam is on.

33

Lower beam

A constant level signal is formed when the lower beam is on.

34

Rear fog lights

A constant level signal is formed when the rear fog lights are on.

35

Seat belts

A constant level signal is formed if any of the preprogrammed seat belts is 

fastened.

36

Driver/passenger 

presence sensor

A constant level signal is formed if there is a driver or a passenger 

(pre-programmed).

37

Engine assistance 

heater switching ON

A constant level signal is formed according to the engine assistance heater 

operation algorithm (taking into account temperature, engine rpm, ignition).

38 Right turn switch 

status

A constant level signal is formed for the time the right turn is on.

39 Left turn switch status

A constant level signal is formed for the time the left turn is on.

Summary of Contents for AutoCAN-F v6

Page 1: ...www TEC electronics ru AutoCAN F v6 Technical manual...

Page 2: ...or which the controller is designed along with its functional features information please refer to the Integrator program from www tec electronics ru Module Inputs Outputs For port contacts enumeratio...

Page 3: ...and subgroup were assigned the controller shall be reset to the factory settings prior to interfacing Two interfacing options are available Automatic interfacing Upon connecting to the vehicle CAN bu...

Page 4: ...nds 6 Enter the subgroup number by pressing the built in button the corresponding number of times Check correctness of the group and subgroup assignment by checking light signals group number pause su...

Page 5: ...1 3 1 single wire pulse negative 2 single wire pulse positive 3 single wire pulse negative when Central Lock status is not available 7 Alternate Hazard Lights control algorithm via output no 2 1 5 1...

Page 6: ...o 8 Parking Distance Control PDC system algorithm Activation on rear gear Front and rear parking sensors are activated upon shifting the transmission to R or with the control button and deactivated wh...

Page 7: ...1 39 15 Ignition 10 Programmable output 20 1 39 12 Trunk 11 Programmable output 21 1 39 12 Hood 12 Programmable output 22 1 39 26 Handbrake 13 Programmable output 9 1 13 1 Activate Central Lock Comfo...

Page 8: ...n the Security mode trunk doors hood opening Also it gives signals when arming disarming the vehicle This function can be used in the vehicles that are not equipped with the factory alarm system The s...

Page 9: ...dal pressed 26 Handbrake A constant level signal is formed when the vehicle is put on the handbrake 27 External lights A constant level signal is formed with the external lights on 28 Timer Channel Co...

Page 10: ...is used for managing the Parking Distance Control function with an external button 10 Hood control The function is used when information about the hood position is not available in the vehicle CAN bus...

Page 11: ...signals and the doors will be assigned to this output If you do not press the brake pedal and exit current option programming the controller will save its previous condition Release the brake pedal a...

Page 12: ...indicated in the output You shall stay on each seat for at least 2 seconds Press the brake pedal again The controller will inform about the option condition with series of 36 light signals If you do n...

Page 13: ...1 second Make a pause of about 2 seconds between the digits In case you have made and error when entering the PIN code after about 3 seconds an audible signal is heard meaning that the PIN code shall...

Page 14: ...lt in LED see Fig 2 The LED illuminates at the moment any of the below parameters are activated door opening brake pedal pressing etc and stays illuminated for 5 seconds or until this parameter is dea...

Page 15: ...Data and Operating Conditions Characteristic Value Power supply voltage V 9 15 Max current consumption in operating mode mA 750 Max current consumption in standby mode mA 1 Operation temperature C 40...

Page 16: ...16 www TEC electronics ru TEC 63062 1 AutoCAN Fv6...

Reviews: