background image

15

www.TEC-electronics.ru

TEC-63062-1 AutoCAN-Fv6

Factory Reset

The controller has the procedure for resetting all the programmable settings, which is used for 

erasing the vehicle model settings from the non-volatile memory and restoring all the other program-

mable option settings to the factory ones.

For factory reset:

• Disconnect the controller from power supply and CAN bus.

• Press and hold the built-in button.

• While holding the built-in button, supply the power to the controller (the CAN bus must remain

disconnected). The controller will give intermittent light signals.

• Disconnect the power supply and release the built-in button.

Table 5. Technical Data and Operating Conditions

Characteristic

Value

Power supply voltage, V

9 ... 15

Max. current consumption in operating mode, mA

750

Max. current consumption in standby mode, mA

1

Operation temperature, °C

– 40 ... + 85

Storage temperature, °C

– 40 ... + 85

Maximum relative air humidity, %

95

Delivery Set

Description

Number

1

Central unit

1 pc.

2

Wire harness with a connector

1 pc.

3

Technical Description

1 pc.

4

Package

1 pc.

Product warranty period is 3 years from the date of purchase if installed in accordance with the 

installation instructions. Please contact your vendor company upon any warranty case.

Manufactured by TEC Electronics Ltd.

Certificate of Conformity No. C-RU.AG92.V.32319

The product complies with the requirements of the Technical Regulations:

Technical Regulations on Safety of Wheeled Vehicles

(the Russian Federation Government DecreeNo. 720of 10/09/2009)

Summary of Contents for AutoCAN-F v6

Page 1: ...www TEC electronics ru AutoCAN F v6 Technical manual...

Page 2: ...or which the controller is designed along with its functional features information please refer to the Integrator program from www tec electronics ru Module Inputs Outputs For port contacts enumeratio...

Page 3: ...and subgroup were assigned the controller shall be reset to the factory settings prior to interfacing Two interfacing options are available Automatic interfacing Upon connecting to the vehicle CAN bu...

Page 4: ...nds 6 Enter the subgroup number by pressing the built in button the corresponding number of times Check correctness of the group and subgroup assignment by checking light signals group number pause su...

Page 5: ...1 3 1 single wire pulse negative 2 single wire pulse positive 3 single wire pulse negative when Central Lock status is not available 7 Alternate Hazard Lights control algorithm via output no 2 1 5 1...

Page 6: ...o 8 Parking Distance Control PDC system algorithm Activation on rear gear Front and rear parking sensors are activated upon shifting the transmission to R or with the control button and deactivated wh...

Page 7: ...1 39 15 Ignition 10 Programmable output 20 1 39 12 Trunk 11 Programmable output 21 1 39 12 Hood 12 Programmable output 22 1 39 26 Handbrake 13 Programmable output 9 1 13 1 Activate Central Lock Comfo...

Page 8: ...n the Security mode trunk doors hood opening Also it gives signals when arming disarming the vehicle This function can be used in the vehicles that are not equipped with the factory alarm system The s...

Page 9: ...dal pressed 26 Handbrake A constant level signal is formed when the vehicle is put on the handbrake 27 External lights A constant level signal is formed with the external lights on 28 Timer Channel Co...

Page 10: ...is used for managing the Parking Distance Control function with an external button 10 Hood control The function is used when information about the hood position is not available in the vehicle CAN bus...

Page 11: ...signals and the doors will be assigned to this output If you do not press the brake pedal and exit current option programming the controller will save its previous condition Release the brake pedal a...

Page 12: ...indicated in the output You shall stay on each seat for at least 2 seconds Press the brake pedal again The controller will inform about the option condition with series of 36 light signals If you do n...

Page 13: ...1 second Make a pause of about 2 seconds between the digits In case you have made and error when entering the PIN code after about 3 seconds an audible signal is heard meaning that the PIN code shall...

Page 14: ...lt in LED see Fig 2 The LED illuminates at the moment any of the below parameters are activated door opening brake pedal pressing etc and stays illuminated for 5 seconds or until this parameter is dea...

Page 15: ...Data and Operating Conditions Characteristic Value Power supply voltage V 9 15 Max current consumption in operating mode mA 750 Max current consumption in standby mode mA 1 Operation temperature C 40...

Page 16: ...16 www TEC electronics ru TEC 63062 1 AutoCAN Fv6...